Stud Health Technol Inform · Jan 2008
Comparative StudyBiomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw.
- Amir A Al-Munajjed, Joachim Hammer, Edgar Mayr, Michael Nerlich, and Andreas Lenich.
- University of Applied Sciences Regensburg, Labor für Werkstoffkunde und Metallographie, Germany. aalmunajjed@rcsi.ie
- Stud Health Technol Inform. 2008 Jan 1;133:1-10.
AbstractProximal femur fractures are of main concern for elderly and especially osteoporotic patients. Despite advanced implant modifications and surgical techniques, serious mechanical complication rates between 4-18% are found in conventional osteosyntheses of proximal femur fractures. Clinical complications such as the rotation of the femoral head and the cut-out phenomenon of the fracture fixation bolt are often diagnosed during post-operative treatments. Therefore, efforts in new intramedulary techniques focus on the load bearing characteristics of the implant by developing new geometries to improve the implant-tissue interface. The objective of this investigation was to analyse the osteosynthesis/femur head interaction of two commonly used osteosyntheses, one with a helical blade and the other one with a screw design under different loading conditions. For the comparative investigation the helical blade of the Proximal Femur Nail Antirotation was investigated versus the screw system of the Dynamic Hip Screw. After implantation in a femoral head the loads for rotational overwinding of the implants were analysed. Pull-out forces with suppressed rotation were investigated with analysis of the influence of the previous overwinding. All investigations were performed on human femoral heads taken of patients with average age of 70.3+/-11.8. The bone mineral densities of the human specimens were detected by QCT-scans (average BMD: 338.9+/- 61.3$\frac[\mathit[mg]][\mathit[cm];[3]]$) Prior to cadaveric testing the experimental set-up was validated and special influences were analysed by the use of synthetic foam blocks (Sawbone). The helical blade showed a significant higher torque for the rotation of the femoral head compared to the screw system. The pull-out forces of the blade were substantially lower than of the comparative screw. Taken together the helical blade showed a higher potential of rotational stability, but after a rotation the lower pull-out forces demonstrate a higher degree of damage to the femoral head.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.