• Am. J. Crit. Care · Jul 1993

    ST segment monitoring for coronary artery reocclusion following thrombolytic therapy and coronary angioplasty: identification of optimal bedside monitoring leads.

    • B J Drew and L A Tisdale.
    • Department of Physiological Nursing, University of California San Francisco 94143-0610.
    • Am. J. Crit. Care. 1993 Jul 1;2(4):280-92.

    BackgroundBedside ST segment monitors analyze only one precordial lead and one, two or three limb leads. The precordial lead V1 (or V6 if V1 is not feasible) has been recommended for bedside monitoring because of its value in diagnosing cardiac rhythms with a wide QRS complex. Thus, the remaining lead choices for ST monitoring are limited to the six limb leads.PurposeTo determine which of the limb leads in conjunction with V1 or V6 provides the greatest sensitivity for myocardial ischemia, a study was undertaken.MethodA total of 30 vessel-unique ischemic episodes were analyzed prospectively using continuous 12-lead electrocardiographic recordings in patients with acute myocardial infarction (n = 2) and patients undergoing coronary angioplasty (n = 25).ResultsIschemic changes were evident in all cases using the full 12-lead electrocardiogram. Right coronary artery-related ischemia was detected in all cases using a single-lead III or aVF. In the group as a whole, the best combinations were: V1 + aVF, V1 + III, V6 + III, and V6 + aVF. Two patients developed sudden coronary artery reocclusion in the cardiac care unit after successful angioplasty. In both, leads identified in the cardiac catheterization laboratory as sensitive for recording ischemia were excellent choices for detection of reocclusion in the cardiac care unit.Conclusions12-lead electrocardiogram recordings during coronary angioplasty balloon inflation provide excellent guidance for postprocedure lead selection decisions. The most valuable limb leads for detecting ischemia due to abrupt artery closure are leads III and aVF, either of which is more sensitive than the routinely monitored lead II. The precordial leads valuable for arrhythmia monitoring, V1 and V6, are seldom sensitive in detecting ischemia in these patients.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…