• Am J Infect Control · Jun 2000

    Association between implementation of CDC recommendations and ventilator-associated pneumonia at selected US hospitals.

    • L P Manangan, S N Banerjee, and W R Jarvis.
    • Hospital Infections Program, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, GA 30333, USA.
    • Am J Infect Control. 2000 Jun 1;28(3):222-7.

    BackgroundTo assess whether selected recommendations in the Centers for Disease Control and Prevention "Guideline for Prevention of Nosocomial Pneumonia" were being implemented and having an impact on the occurrence of ventilator-associated pneumonia (VAP) at US hospitals, we surveyed hospitals participating in the National Nosocomial Infections Surveillance (NNIS) system.MethodsWe mailed a questionnaire to the infection control practitioner of each NNIS hospital in 1995 and used data from the NNIS system to calculate annual rates of VAP.ResultsOf the 188 hospitals surveyed, 179 (95%) returned completed questionnaires. Of these, 175 (98%) had implemented the recommended change of mechanical-ventilator breathing circuits at 48-hour or greater intervals. Of 110 hospitals using the hygroscopic condenser-humidifiers or heat-moisture exchangers with ventilators, 102 (93%) changed the hygroscopic condenser-humidifiers or heat-moisture exchangers routinely, and of 98 hospitals using bubbling humidifiers, 96 (98%) used sterile water to fill these humidifiers. Other practices for which the guideline provides no recommendation and their frequency of use by NNIS hospitals include use of hygroscopic condenser-humidifiers or heat-moisture exchangers (110/179 [61%]) and use of bacterial filters in anesthesia machines (128/171 [61%]). There was a significant decrease in the VAP rate from 1987 to 1998.ConclusionMost NNIS hospitals had implemented selected recommendations in the Centers for Disease Control and Prevention "Guideline for Prevention of Nosocomial Pneumonia" before the final publication of the revised guideline. Further studies are needed to assess the impact of these recommendations on the occurrence of VAP.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…