• Kyobu Geka · Aug 2013

    [Clinical evaluation of intraoperative cardiac output measurement by a new arterial pressure waveform analysis method( FloTrac/Vigileo) in open heart surgery].

    • Hiroshi Furukawa, Akihiko Ohkado, Mitsugi Nagashima, Hiroshi Ohsawa, and Sei-ichi Ichikawa.
    • Department of Cardiovascular Surgery, Cardiovascular Center, Okayama Central Hospital, Okayama, Japan.
    • Kyobu Geka. 2013 Aug 1;66(9):775-83.

    AbstractWe retrospectively evaluated the initial clinical experience of intraoperative cardiac output measurement by a new arterial pressure-based cardiac output (APCO:FloTrac/Vigileo) analysis in patients undergoing open heart surgery. Thirty-two patients (mean age 76.4, range 59 to 90)who underwent cardiac surgery under cardiopulmonary bypass( CPB) from July 2008 to September 2009 in our institute were enrolled in this study. There were 14 women and 18 men. The cardiac operations included 28 valve surgeries and 4 coronary artery bypass grafting. The APCO was introduced initially, then a continuous cardiac output (CCO:Swan-Ganz catheter) analysis system was established following the induction of anesthesia. The correlation of both cardiac output measurements was evaluated at 5 time points, T1:induction of anesthesia, T2:sternotomy, T3:after weaning from CPB, T4:closure of the chest, and T5:arrival at intensive care unit. There were no serious complications related to APCO and CCO. The correlation between APCO and CCO was evaluated by Bland-Altman plot analysis. The percentages of correlation between both groups were T1:81.2%, T2:78.1%, T3:59.4%, T4:62.5%, and T5:65.6%. A good correlation was shown in all 6 patients with atrial fibrillation at T1 and T2. No correlation was shown in the 3 patients with left ventricular( LV) dysfunction below LVEF 40%, 1 case at T3, all 3 cases at T4, and 2 cases at T5. Before the institution of CPB, 3 of the 6 at T1 and 3 of the 7 at T2 in whom no correlation was shown, had severe aortic valve insufficiency (AVI).From these results, APCO appears to be an acceptable device to evaluate the intraoperative cardiac output measurement compared with CCO, except in patients with LV dysfunction or AVI at some time points. Further studies will be necessary to elucidate the precise clinical evidence to assess the efficacy of this new analysis device.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.