    Comparison of Doppler, oscillometric, auricular and carotid arterial blood pressure measurements in isoflurane anesthetized New Zealand white rabbits.

    • Linda S Barter and Steven E Epstein.
    • Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, USA.
    • Vet Anaesth Analg. 2014 Jul 1;41(4):393-7.

    ObjectiveTo assess agreement between carotid arterial pressure and auricular arterial, thoracic limb Doppler or thoracic limb oscillometric blood pressure measurements.Study DesignProspective experimental study.AnimalsSix adult New Zealand white rabbits.MethodsRabbits were anesthetized with isoflurane in oxygen at 1, 1.5 and 2 MAC on two separate occasions. Catheters in the auricular and the contralateral external carotid artery were connected to calibrated pressure transducers via non-compliant tubing. Inflatable cuffs of width equal to approximately 40% of the limb circumference were placed above the carpus on both thoracic limbs with a Doppler transducer placed distal to the cuff on one. Systolic (SAP) and mean (MAP) arterial blood pressure measurements were obtained at each dose, on each occasion. Agreement between measurement techniques was evaluated by repeated measures Bland Altman analysis with carotid pressure as the reference. Variation in bias over the measurement range was evaluated by regression analysis.ResultsCarotid MAP and SAP ranged from 20 to 65 mmHg and 37 to 103 mmHg respectively. Bias and 95% limits of agreement for auricular and oscillometric MAP were 7 (0-14) and -5 (-21-11) mmHg, respectively, and for auricular, oscillometric and Doppler SAP were 23 (8-37), -2 (-24-20) and 13 (-14-39) mmHg, respectively. Bias varied significantly over the measurement range (p < 0.001) for all three SAP techniques but not for MAP measurements.Conclusions And Clinical RelevanceLimits of agreement for all measurements were large but less so for MAP than SAP. Variation in bias with SAP should be considered when using these measurements clinically.© 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…