Comparative Study
Suitability of Capillary Blood Glucose Analysis in Patients Receiving Vasopressors.
- Myra F Ellis, Kesi Benjamin, Morgan Cornell, Kelsey Decker, Debra Farrell, Lynn McGugan, Gloria P Porter, Helen Shearin, Yanfang Zhao, and Bradi B Granger.
- Duke University Hospital, Durham, NC, USA.
- Am. J. Crit. Care. 2013 Sep 1;22(5):423-9.
BackgroundGlycemic control in critically ill patients decreases infection and mortality. Patients receiving vasopressors have altered peripheral perfusion, which may affect accuracy of capillary blood glucose values measured with point-of-care devices.ObjectivesTo compare capillary and arterial glucose values measured via point-of-care testing (POCT) with arterial glucose values measured via clinical chemistry laboratory testing (CCLT) in patients after cardiothoracic surgery. To determine if vasopressors or diminished peripheral perfusion influence the accuracy of POCT values.MethodsIn a prospective, convenience sample of 50 adult postoperative cardiothoracic patients receiving insulin and vasopressors, 162 samples were obtained simultaneously from capillary and arterial sites during insulin infusion and tested via both POCT and CCLT. Clarke error grid analysis and ISO 15197 were used to analyze level of agreement. Two-way analysis of variance was used to analyze differences in glucose values with respect to vasopressor use and peripheral perfusion.ResultsAn unacceptable level of agreement was found between the capillary POCT results and arterial CCLT results (only 88.3% of values fell in zone A, or within the ISO 15197 tolerance bands). Arterial POCT results showed acceptable (94.4%) agreement with CCLT results. Vasopressor use had a significant effect on the accuracy of arterial blood glucose values (F=15.01; P<.001).ConclusionsEven when the more accurate POCT with arterial blood is used, blood glucose values are significantly less accurate in patients receiving more than 2 vasopressors than in patients receiving fewer vasopressors. CCLT may be safer for titrating insulin doses in these patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.