• Clinical biochemistry · Jul 1997

    Evaluation of i-STAT portable clinical analyzer in a neonatal and pediatric intensive care unit.

    • J N Murthy, J M Hicks, and S J Soldin.
    • Department of Laboratory Medicine, Children's National Medical Center, Washington, DC 20010, USA.
    • Clin. Biochem. 1997 Jul 1;30(5):385-9.

    ObjectiveTo evaluate the Point-of-Care (POC) i-STAT system for measuring blood gases (pH, pCO2, pO2) and whole blood electrolytes (sodium, Na+, potassium, K+ and ionized calcium, iCa2+) in the neonatal and pediatric intensive care units.Design And MethodsThe i-STAT system was evaluated for imprecision, necessity of running quality control and accuracy. Comparison of patients' samples analyzed by the i-STAT system and the Ciba Coming 288 blood gas analyzer were performed. The reliability of the i-STAT system when performed by non-laboratory personnel was assessed.ResultsThe system was evaluated for imprecision and linearity using three concentrations of aqueous standards. Except for pO2, the %CVs were < 3.0 for all the analytes (pH, pCO2, Na+, K+ and iCa2+) at all the three concentrations. Using whole blood studies the precision data gave %CVs that were < 3.5 for all the analytes. Linearity studies showed good linearity over the five different concentrations tested. Comparison of the i-STAT and the Ciba Coming 288 blood gas analyzer was assessed by split sample measurement. Patients' results from the i-STAT correlated well with the Ciba Coming 288 blood gas analyzer (r = 0.99 for pH, pCO2 and pO2 and 0.95 to 0.99 for Na+ and K+) with the exception of iCa2+ (r = 0.73). There was no significant difference in the results when operated by PICU/NICU nurses or laboratory personnel. A further study was made to assess whether routine quality control (QC) samples are necessary when using the i-STAT system. The regression analysis (slope and correlation coefficient) of the results from instruments run with and without QC samples gave results close to 1, indicating that there is no need to run additional quality control (QC).ConclusionThe POC testing analyzer i-STAT is a reliable alternative to the traditional blood gas analyzers and provides marginal improvement in turnaround time when compared with the service received from the PICU/NICU laboratory. Costs need to be carefully controlled.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.