• Ann. Thorac. Surg. · Feb 2008

    Randomized Controlled Trial Multicenter Study

    Coronary artery bypass graft failure after on-pump and off-pump coronary artery bypass: findings from PREVENT IV.

    • Mitchell J Magee, John H Alexander, Gail Hafley, T Bruce Ferguson, C Michael Gibson, Robert A Harrington, Eric D Peterson, Robert M Califf, Nicholas T Kouchoukos, Morley A Herbert, Michael J Mack, and PREVENT IV Investigators.
    • Cardiopulmonary Research Science and Technology Institute, Dallas, Texas, USA. mmagee@csant.com
    • Ann. Thorac. Surg. 2008 Feb 1;85(2):494-9; discussion 499-500.

    BackgroundThis analysis compares 1-year vein graft patency and major adverse cardiac and cerebral events (MACCE [death, myocardial infarction, or stroke]) in on-pump and off-pump patients enrolled in PREVENT IV (the PRoject of Ex-vivo Vein graft ENgineering via Transfection IV).MethodsThe PREVENT IV was a multicenter (107 sites) randomized trial of edifoligide to prevent vein graft failure from neointimal hyperplasia in 3,014 patients undergoing primary, isolated coronary artery bypass grafting (CABG) with at least two vein grafts. One-year angiographic follow-up was completed on 1,920 patients (4,736 grafts) with MACCE follow-up on 99.4% of enrolled patients.ResultsIn all, 2,377 procedures (78.9%) were on pump and 637 (21.1%) were off pump. On-pump patients had more chronic lung disease (17% versus 11%; p < 0.001), congestive heart failure (10% versus 7%; p = 0.03), lower mean ejection fraction (50% versus 55%; p < 0.001), and worse target artery quality (good 63.8% versus 68.1%; fair 26.4% versus 22.7%; poor 9.8% versus 9.2%; p < 0.001). Vein graft failure (more than 75% graft stenosis) in on- versus off-pump patients was 25.3% versus 25.7% (p = 0.62). After adjusting for differences in significant predictors of vein graft failure (target artery quality, surgery time, endoscopic vein harvest, more than 1 distal anastomosis/graft, and patient weight), the odds of vein graft failure was 0.82 (95% confidence interval: 0.67 to 1.00; p = 0.05) for on-pump versus off-pump patients. One-year mortality for on- versus off-pump patients was 3.3% versus 2.5% (p = 0.30); and MACCE was 15.4% versus 11.3% (p = 0.01). The adjusted hazard ratio for 1-year MACCE was 1.31 (95% confidence interval: 1.01-1.69; p = 0.01) for on pump versus off pump.ConclusionsObserved saphenous vein failure rate was 25% in both groups. One-year clinical outcomes (MACCE) were better with off-pump than with on-pump CABG, suggesting benefits not related to vein graft patency.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.