Comparative StudyThe mean machine; accurate non-invasive blood pressure measurement in the critically ill patient.
- Sandy Muecke, Andrew Bersten, and John Plummer.
- Department of Critical Care Medicine, Flinders University, Adelaide, SA, Australia. sandra.muecke@flinders.edu.au
- J Clin Monit Comput. 2009 Oct 1;23(5):283-97.
ObjectiveAccurate indirect prehospital blood pressure measurement in the critically ill patient remains an important challenge to both patient management and prehospital research. Ambulatory blood pressure measuring devices have not been trialled for prehospital use in critically ill patients. Prior to prehospital validation where conditions are suboptimal, we aimed to test under favourable conditions in the Intensive Care Unit, a selection of ambulatory devices that may be suitable for use in the field.MethodsSystolic, diastolic and mean pressures of three ambulatory devices were compared to the average of 1 min of independently recorded, high fidelity intra-arterial reference pressures. Eighteen critically ill patients were recruited. Device performance was required to fulfil the Association for the Advancement of Medical Instrumentation (AAMI) protocol. Additionally, agreement between measurement methods was examined using Bland-Altman plots. Two-level linear mixed model analyses were under- taken.ResultsFor each device, 150 paired measurements (arterial reference and device) were analysed. According to the AAMI protocol, no device measured systolic pressures accurately. One device measured diastolic pressures accurately. Integrated mean pressures were accurately measured by all devices. Overall, SunTech Medical's Oscar 2 performed best with mean pressure error not exceeding 17 mmHg. For this device, Bland-Altman plots showed uniform agreement across a wide range of mean pressures. Two-level linear mixed effects analyses showed that Oscar 2 mean error reduced during vasopressor use by (-) 3.9 mmHg (95% CI -5.9, -1.9; P < 0.001), and clinically, performance was little affected during mechanical ventilation. For the Oscar 2, there was up to (-) 7.0 mmHg (95% CI -10.3, -3.5; P < 0.001) l ess mean error during hypotension compared to normo- tension.ConclusionsIn the Intensive Care Unit, the performance of one device, the Oscar 2, surpassed the others and fulfilled the AAMI protocol criteria for mean pressure measurement. This device is suitable for prehospital validation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.