Emergency (Tehran, Iran) · Jan 2013
Sonographic Optic Nerve Sheath Diameter as a Screening Tool for Detection of Elevated Intracranial Pressure.
- Afshin Amini, Razieh Eghtesadi, Ali Mohammad Feizi, Behnam Mansouri, Hamid Kariman, Ali Arhami Dolatabadi, Hamidreza Hatamabadi, and Ali Kabir.
- Department of Emergency Medicine, Imam Hossein Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
- Emerg (Tehran). 2013 Jan 1;1(1):15-9.
IntroductionTimely diagnosis and treatment of post-traumatic elevated intracranial pressure (EICP) could be reduced morbidity and mortality, and improved patients' outcome. This study is trying to evaluate the diagnostic accuracy of sonographic optic nerve sheath diameter (ONSD) in detection of EICP.MethodsSonographic ONSD of patients with head trauma or cerebrovascular accident suspicious for EICP were evaluated by a trained chief resident of emergency medicine, who was blind to the clinical and brain computed tomography scan (BCT) findings of patients. Immediately after ultrasonography, BCT was performed and reported by an expert radiologist without awareness from other results of the patients. Finally, ultrasonographic and BCT findings regarding EICP were compared. To evaluate the ability of sonographic ONSD in predicting the BCT findings and obtain best cut-off level, receiver operating characteristic (ROC) curve were used. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of sonographic ONSD in determining of EICP was calculated. P < 0.05 was considered as statistically significant.ResultsThere were 222 patients (65.3% male), with mean age of 42.2±19.5 years (range: 16-90 years). BCT showed signs of EICP, in 28 cases (12.6%). The means of the ONSD in the patients with EICP and normal ICP were 5.5 ± 0.56 and 3.93 ± 0.53 mm, respectively (P<0.0001). ROC curve demonstrated that the best cut off was 4.85 mm. Sensitivity, specificity, PPV, NPV, PLR, and NLR of ONSD for prediction of EICP were 96.4%, 95.3%, 72.2%, 98.9%, 20.6, and 0.04, respectively.ConclusionSonographic diameter of optic nerve sheath could be considered as an available, accurate, and noninvasive screening tool in determining the elevated intracranial pressure in cases with head trauma or cerebrovascular accident.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.