• Der Anaesthesist · Dec 2010

    Guideline

    [Prevention of infections under anesthetic breathing with breathing filters: concerted recommendations of the Deutsche Gesellschaft für Krankenhaushygiene e.V. (DGKH) and the Deutsche Gesellschaft für Anästhesiologie und Intensivmedizin e.V. (DGAI)].

    • R Kranabetter, A Kramer, J Rathgeber, K Züchner, O Assadian, G Daeschlein, N-O Hübner, E Dietlein, M Exner, M Gründling, C Lehmann, M Wendt, B M Graf, D Holst, L Jatzwauk, B Puhlmann, T Welte, A R Wilkes, Deutschen Gesellschaft für Krankenhaushygiene, and Deutschen Gesellschaft für Anästhesiologie und Intensivmedizin.
    • hr.kranabetter@o2online.de
    • Anaesthesist. 2010 Dec 1; 59 (12): 112411321124-32.

    AbstractAn interdisciplinary working group from the German Society of Hospital Hygiene (DGKH) and the German Society for Anesthesiology and Intensive Care (DGAI) worked out the following recommendations for infection prevention during anesthesia by using breathing system filters (BSF). The BSF shall be changed after each patient. The filter retention efficiency for airborne particles is recommended to be >99% (II). The retention performance of BSF for liquids is recommended to be at pressures of at least 60 hPa (=60 mbar) or 20 hPa above the selected maximum ventilation pressure in the anesthetic system.The anesthesia breathing system may be used for a period of up to 7 days provided that the functional requirements of the system remain unchanged and the manufacturer states this in the instructions for use. The breathing system and the manual ventilation bag are changed immediately after the respective anesthesia if the following situation has occurred or it is suspected to have occurred: Notifiable infectious disease involving the risk of transmission via the breathing system and the manual bag, e.g. tuberculosis, acute viral hepatitis, measles, influenza virus, infection and/or colonization with a multi-resistant pathogen or upper or lower respiratory tract infections. In case of visible contamination e.g. by blood or in case of defect, it is required that the BSF and also the anesthesia breathing system is changed and the breathing gas conducting parts of the anesthesia ventilator are hygienically reprocessed.Observing of the appropriate hand disinfection is very important. All surfaces of the anesthesia equipment exposed to hand contact must be disinfected after each case.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…