-
Comparative Study
Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?
- M Königshausen, L Kübler, H Godry, M Citak, T A Schildhauer, and D Seybold.
- Department of General and Trauma Surgery, BG Universitätsklinikum Bergmannsheil, Ruhr-Universität Bochum, Bürkle-de-la-Camp-Platz 1, 44789 Bochum, Germany. m.koenigshausen@web.de
- Injury. 2012 Feb 1;43(2):223-31.
IntroductionThe surgical treatment of displaced proximal humeral fractures (ORIF) is a perpetual challenge to the surgeon. For this reason, the principle of polyaxiality was developed to provide an improved primary stability of the fracture through better anchorage of the screws, especially in osteoporotic bone. The aim of this study was to present clinical results with the polyaxial locking plate in the operative treatment of proximal humerus fractures in order to determine whether the technique of polyaxiality leads to better functional outcome and lower complication rates in comparison to monoaxial plates in the literature.Patients And MethodsSeventy-three patients with displaced proximal humeral fractures were treated surgically with the polyaxial locking Suture Plate™ (Arthrex(®)) between 03/2007 and 06/2009. Fifty-two of the patients (mean age, 69.9 ± 12.1) were included in a radiographical and clinical examination using the Constant score (CS) and the Disabilities of the Arm, Shoulder and Hand score (DASH).ResultsThe follow-up examinations were on average 13.9 ± 4.5 months (10-27 months) after surgical treatment. The mean CS of the patients was 66.0 ± 13.7 points, the age- and gender-related CS was 90.9% ± 20.0% and the mean DASH score was 23.8 ± 19.8 points for the injured side. The patients with a nearly anatomical reduction of their fracture (n = 13) reached a significantly higher CS (75.1 ± 8.5; p = 0.004) and DASH-score (13.6 ± 11.6; p = 0.043) and none of these patients had a complication. The complications were identified in 12 (23.1%) cases, 5 of which involved loss of reduction. All of these 5 cases were lacking of initial medial column support and 4 of which were type C2.3 AO-Classification.ConclusionThe data show that the combination of angular stability with the possibility of variable polyaxial screw direction is a good concept for reduction and fixation of displaced proximal humeral fractures, but anatomical reduction and medial support remain important preconditions for a good outcome. However, a significantly lower rate of complications or better clinical outcome than that reported in the literature could not be found.Copyright © 2011 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.