Pediatr Crit Care Me · May 2004
Comparative StudyComparison of solute clearance in three modes of continuous renal replacement therapy.
- Daiva Parakininkas and Larry A Greenbaum.
- Division of Pediatric Critical Care and Division of Pediatric Nephrology, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
- Pediatr Crit Care Me. 2004 May 1;5(3):269-74.
ObjectivesTo compare the clearances of low molecular weight molecules using three modalities of continuous renal replacement therapy (CRRT) at the low blood flow rates typically used in pediatric patients.DesignA controlled, in vitro laboratory study.SettingResearch laboratory of a health sciences university.SubjectsAN69 dialysis hemofilter.InterventionsCRRT was performed using a 0.6 m(2) AN69 hemofilter. Human whole blood and plasma were combined to achieve a hematocrit of approximately 30%. Urea and creatinine were added to obtain concentrations of approximately 54 mmol/L of blood urea nitrogen and 1770 micromol/L of creatinine. Clearance data for urea and creatinine at a blood flow rate of 60 mL/min were generated using predilution continuous venovenous hemofiltration (CVVH), postdilution CVVH, and continuous venovenous hemodialysis (CVVHD).Measurements And Main ResultsClearance of all three modalities was compared at a replacement solution (CVVH) or dialysate (CVVHD) flow rate of 16.7% of the blood flow rate. Both postdilution CVVH and CVVHD had a urea clearance of 11.3 mL/min, which was 15% greater than the 9.8 mL/min urea clearance of predilution CVVH (p <.005). Creatinine clearance with postdilution CVVH (10.7 mL/min) was 15% greater than the 9.0 mL/min clearance produced by predilution CVVH (p < 0.01). Predilution CVVH and CVVHD were compared at a flow rate of either replacement solution (CVVH) or dialysate (CVVHD) of 33% and 50% of the blood flow rate. Postdilution CVVH was not performed at high ultrafiltration rates due to the potential problem of hemoconcentration. CVVHD clearances of urea and creatinine were statistically superior to predilution CVVH at both flow rates.ConclusionsCVVHD was superior to predilution CVVH for clearance of urea and creatinine. Postdilution CVVH and CVVHD gave nearly equivalent clearances. At the low blood flow rates used in pediatric patients, which raise concerns about high ultrafiltration during postdilution CVVH causing excessive hemoconcentration and filter clotting, CVVHD appears to be the optimal modality for maximizing clearance of small solutes during CRRT.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.