- Sophia Horster, Hans Joachim Stemmler, Jakob Sparrer, Johanna Tischer, Andreas Hausmann, and Sandra Geiger.
- Medical Dept. II, Ludwig-Maximilians University of Munich, Campus Grosshadern, Munich, Germany.
- Acta Cardiol. 2012 Apr 1;67(2):177-85.
BackgroundAggressive mechanical ventilation can markedly and unpredictably affect cardiac function. The fall in cardiac output (CO) is due to a reduction in left ventricular stroke volume (SV). The aim of the present pilot study was to assess the effects of different positive end-expiratory pressure (PEEP) levels on circulatory function and to compare them with continuous wave (CW)-Doppler ultrasound cardiac output monitoring (USCOM) and a thermodilution-based haemodynamic monitoring system (PiCCO).MethodsTwenty mechanically ventilated (PEEP < or = 10 mbar) adult patients (female n = 6, male n = 14, mean age 62 years, mean SAPS II-score 48.5), the majority with pneumonia and septic shock) were followed with USCOM and PiCCO at stepwise increased PEEP-levels from 0-10 mbar (1 mbar steps). The changes in CO/SV were recorded.ResultsWith both methods, an increase of PEEP resulted in a decrease of SV and CO. Although the absolute decrease was consistently higher by USCOM, the changes of the parameters were qualitatively comparable. CO fell from 8.83 L/min (+/- 2.39) by 0.4 L/min to 8.49 L/min (+/- 2.48) with PiCCO and from 9.3 L/min (+/- 3.43) by 1.0 L/min to 8.3 L/min (+/- 3.2) with USCOM. The median CO/SV fell by 4.5%/5.2% with PiCCO and 10.8%/9% with USCOM, respectively. Correlation of CO values with the two methods by Bland-Altman yielded comparable results (mean percentage error at PEEP 0 mbar 13%, PEEP 10 mbar 18%). An adequate flow signal with USCOM was achieved in all patients.ConclusionsA significant influence of mechanical ventilation with PEEP on haemodynamic parameters was evident both with USCOM and PiCCO. While thermodilution methods like PiCCO are well established but time-consuming and invasive, CW-Doppler based USCOM constitutes an important tool for easy, rapid and reliable diagnosis and haemodynamic monitoring of critically ill patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.