    [Foreseeable variation in parameters measured at implant and follow-up of permanent pacemaker active fixation electrodes].

    • A Canabal, V Hortigüela, A Raigal, P Sánchez, M Sánchez, C Marco, E Fernández, and J A Márquez.
    • Servicio de Medicina Intensiva, Hospital Virgen de la Salud de Toledo, España. alcanabal@telefonica.net
    • Med Intensiva. 2012 May 1;36(4):270-6.

    ObjectivesTo analyze the variations in the parameters relative to active fixation electrodes at the time of implantation and over subsequent follow-up during 6 months of the acute phase of implantation.DesignA descriptive, analytical, prospective, observational cohort study was made of consecutive cases over a period of 8 months (April-December 2010).SettingPacing unit of an Intensive Care Unit.Patients Or ParticipantsPatients undergoing permanent pacemaker implantation with active fixation electrodes, implanted in both atrium and ventricle, Interventions: Measurement of variables described with a threshold analyzer during electrode fixation and at different times during the study, Main compared variables: threshold, impedance and intrinsic activity (both atrial and ventricular) before and after fixation, at 48 hours, at one month and 6 months, Comparisons were made using the Student t-test for paired data, assuming significance for p<0,05, and ANOVA to analyze the successive changes over ambulatory follow-up.ResultsWe analyzed 40 patients, with 19 atrial and 40 ventricular electrodes, In fixation, the electrodes showed significant variation in the impedance values of the atrial lead (1,188,53 ± 397,26 vs 610,69 ± 326,30 ohms, p<0,0001) and ventricular lead (1,512,93 ± 718,07 vs 768,80 ± 224,90 ohms, p>0,0001), In the first 48 hours it was coupled with a decrease in ventricular (0,86 ± 0,35 vs 0,48 ± 0,23 volts, p = 0,0001) and atrial pacing threshold (1,10 ± 0,39 vs 0,43 ± 0,23 volts, p = 0,0003), and p-wave sensing (3,61 ± 2,25 vs 2,32 ± 1,09 mV, p = 0,0463), Over follow-up we found the parameters to be stable, with no significant changes.ConclusionsAfter active lead fixation, a fall in impedance of the antrial and ventricular is expected, Over the next 48 hours improvement in atrial and ventricular threshold may occur, in contrast to the sensitivity of the intrinsic activity, which reached significance at the P wave measured after 48 hours, These values stabilize over patient follow-up and do not differ significantly in the studied acute patient course.Copyright © 2011 Elsevier España, S.L. and SEMICYUC. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.