J. Cardiothorac. Vasc. Anesth. · Apr 2007
Comparative StudyThe air-leak test is not a good predictor of postextubation adverse events in children undergoing cardiac surgery.
- Pertti K Suominen, Netta A Tuominen, Jukka T Salminen, Reijo E Korpela, Jaakko G M Klockars, Tomi R Taivainen, and Olli A Meretoja.
- Department of Anesthesia and Intensive Care, Hospital for Children and Adolescents, Helsinki University Central Hospital, Helsinki, Finland. psuominen@hmc.psu.edu
- J. Cardiothorac. Vasc. Anesth. 2007 Apr 1;21(2):197-202.
ObjectiveThe air-leak test is recommended as a method of assessing the appropriate size of an uncuffed endotracheal tube (ETT) in children. The authors' primary objective was to determine whether the air-leak test would predict adverse events and reintubations after the removal of the ETT in children who have undergone cardiac surgery.DesignProspective, observational, clinical study.SettingUniversity tertiary care hospital.PatientsNinety-four children <10 years of age undergoing elective cardiac surgery requiring cardiopulmonary bypass surgery.InterventionsThe attending anesthesiologist assessed air-leak pressure after intubation in the operating room (OR). In addition, the air-leak test was performed in 42 patients before extubation in the pediatric intensive care unit (PICU). The incidence of adverse events and the number of failed extubations were recorded after removal of the ETT.Measurements And Main ResultsEleven of the 94 patients were excluded from the study. Four (4.3%) of the patients died in the PICU before extubation, and 7 patients were excluded for other reasons. The median age of the 83 children was 0.9 years (range 0.01-9.6 years). The total incidences of postextubation adverse events and failed extubations were 30.1% and 8.4%, respectively. An audible air leak < or =25 cmH(2)O airway pressure during the OR phase or before removal of the ETT during the PICU recovery phase had no significant predictive value for the incidence of adverse events (p = 0.63) or reintubations (p = 1.0). The patients undergoing simple and complete operations compared with more complex and incomplete operations had significantly fewer postextubation adverse events (p = 0.03). Neonates did not have a higher risk for postextubation adverse events (p = 0.64) or reintubations (p = 0.26) than older children.ConclusionThe air-leak test did not predict an increased risk for postextubation adverse events and reintubations in children undergoing elective congenital heart surgery.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.