Comparative StudyEnergy expenditure and gas exchange measurements in postoperative patients: thermodilution versus indirect calorimetry.
- L S Brandi, M Grana, T Mazzanti, F Giunta, A Natali, and E Ferrannini.
- Department of Anesthesiology and Intensive Care, University of Pisa, Italy.
- Crit. Care Med. 1992 Sep 1;20(9):1273-83.
ObjectiveTo compare a method of measuring energy expenditure and gas exchange using the Fick principle with the standard indirect calorimetry technique.DesignProspective study of a consecutive sample of postoperative patients. Oxygen consumption (VO2), CO2 production (VCO2), respiratory quotient, and energy expenditure were derived from measurements of variables, including oxygen content and cardiac output. Energy expenditure and gas exchange were measured simultaneously by continuous indirect calorimetry over a 60-min period.SettingSurgical ICU in a university hospital.PatientsTwenty-six consecutive patients (45 to 80 yrs) who underwent sustained surgical trauma. Excluded from the study entry were patients with time-related fluctuations of hemodynamic variables, poor cooperation, patients who required supplemental oxygen, or mechanical ventilation.InterventionsNone.Measurements And Main ResultsWhile the measurements of VO2 and VCO2 by calorimetry and thermodilution were significantly correlated with one another (for VO2, r2 = .93, p less than .001; for VCO2, r2 = .26, p less than .01), VO2 and VCO2 values by indirect calorimetry were consistently greater than VO2 and VCO2 values by the Fick method (p less than .01). The respiratory quotient calorimetric measurements ranged between 0.69 and 0.99, whereas the corresponding thermodilution measurements spread to impossible values, from 0.24 to 1.30 (0.821 +/- 0.07 vs. 0.740 +/- 0.24, p less than .05). There was an insignificant relationship (r2 = .06, p = .21) between the values of respiratory quotient by the two methods. A strong, positive correlation between energy expenditure measured by indirect calorimetry and energy expenditure measured by the Fick method was observed (r2 = .92, p less than .001). The limit of agreement between the two methods was -0.24 +/- 73 kcal/day/m2 (-1.00 +/- 305 kJ/day/m2).ConclusionsIn postoperative patients, while VO2 and energy expenditure measurements by thermodilution are easy to perform and accurate for clinical purposes, VCO2, and respiratory quotient measurements are too imprecise and inaccurate to serve any useful function. Therefore, in those clinical situations in which an evaluation of respiratory quotient and substrate utilization may be useful for purposes of metabolic care of the surgical patient, precise measurements of gas exchange with indirect calorimetry are mandatory.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.