• J Clin Monit Comput · Oct 2007

    Comparative Study

    Forehead reflectance oximetry: a clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery.

    • Andrea Casati, Grazia Squicciarini, Marco Baciarello, Marta Putzu, Alessandra Salvadori, and Guido Fanelli.
    • Department of Anesthesiology, Critical Care and Pain Medicine, University of Parma, Italy.
    • J Clin Monit Comput. 2007 Oct 1;21(5):271-6.

    ObjectiveThis study compared the performance of forehead reflectance and conventional pulse oximetry (SpO(2)) in mechanically ventilated, anesthetized patients undergoing major abdominal surgery with either laparoscopic or laparotomic techniques.MethodsSpO(2) was continuously measured both with a forehead reflectance and a conventional digit sensor in 20 ASA physical status I-III, anesthetized patients undergoing either a laparotomic (group Laparotomy, n = 10) or laparoscopic (group Laparoscopy, n = 10) major abdominal surgery. SpO(2) values measured with the two sensors were continuously recorded at 10-second intervals during the entire procedure, and then analyzed for consistency.ResultsIn group Laparotomy finger and forehead readings remained consistently similar during the study period; on the contrary, in group Laparoscopy forehead SpO(2) readings showed a much wider variability. The mean (95% Confidence Intervals) difference between finger and forehead SpO(2) readings was 2.0% (-1.3% to +6.0%) in group Laparotomy and 2.5% (-3.5% to +8.4%) in group Laparoscopy (p = 0.001); however, in group Laparoscopy the mean difference between digit and forehead SpO(2) values increased from 0.2% (CI(95): -2.1% to +2.5%) during the first hour to 4.5% (CI(95): -2.5% to +11-5%) in the second hour (p = 0.0005), and 3.1% (CI(95): -2.4% to + 8.6%) in the third hour of surgery (p = 0.0005). Clinically relevant desaturation (decrease of SpO(2) < 89% for > or =30 s) detected with the forehead sensor in the Laparoscopy group was significantly more frequent and longer lasting than with conventional digit sensor. No differences were observed in group Laparotomy.ConclusionsForehead reflectance oximetry is as accurate as conventional digit based oximetry in mechanically ventilated patients undergoing laparotomic surgery in the supine position, but is significantly influenced by patient positioning and pneumoperitoneum during laparoscopic surgery.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…