• Vet Anaesth Analg · May 2016

    Comparative Study Clinical Trial

    Comparison of invasive and noninvasive blood pressure measurements in anaesthetized horses using the Surgivet V9203.

    • Eleanor A Drynan, Mara Schier, and Anthea L Raisis.
    • Department of Anaesthesia, School of Veterinary and Biomedical Sciences, Murdoch University Murdoch, Murdoch, Australia.
    • Vet Anaesth Analg. 2016 May 1; 43 (3): 301-8.

    ObjectivesTo determine the bias and precision of noninvasive versus invasive blood pressure measurements obtained using the Surgivet V9203 in anaesthetized horses; to compare these with the current American College of Veterinary Internal Medicine Hypertension Consensus Panel (AHCP) and Veterinary Blood Pressure Society (VBPS) recommendations; and to investigate whether noninvasive blood pressure monitoring could be a clinically useful alternative to invasive blood pressure monitoring in anaesthetized horses.Study DesignProspective clinical study in a university teaching hospital.AnimalsForty-three horses with an average weight of 485 ± 90 kg and a mean age of 103.4 ± 57.6 months.MethodsArterial blood pressure (BP) was measured noninvasively (NIBP) via a cuff placed over either the ventral coccygeal artery or the metacarpal artery, and invasively (IBP) via a catheter in either the facial artery or the metatarsal artery. A total of 143 paired readings were obtained. Comparison of measurements was carried out using the Bland-Altman method. Analysis was performed using all the data, and these data were subdivided according to the position of the horse and the magnitude of the pressure measurement. To determine the accuracy of the noninvasive measurements, the calculated precision and bias were compared with AHCP and VBPS guidelines.ResultsFor all categories, NIBP measurements were generally lower than IBP measurements. For pooled data, the bias and precision for systolic arterial pressure (SAP) were 6.8 and 11.9 mmHg; for mean arterial pressure (MAP) the values were 1.9 and 10.0 mmHg; and for diastolic arterial pressure (DAP) they were 5.7 and 10.8 mmHg. The bias and precision for MAP and DAP measurements were within the recommended guidelines defined by the AHCP and VBPS.Conclusions And Clinical RelevanceThese results suggests that systolic, mean and diastolic NIBP measured using the Surgivet V9203 are a clinically acceptable alternative to IBP measurements in anaesthetized horses undergoing routine elective surgeries.© 2015 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.