    ObjectiveTo evaluate the modular sutureless Arbor Trilogy Aortic Valve System (Arbor Surgical Technologies, Irvine, Calif), designed for minimally invasive aortic valve replacement.MethodsIn a prospective multicenter study, 32 patients with severe aortic valve stenosis underwent aortic valve replacement with the Trilogy valve between 2006 and 2008. Concomitant coronary artery bypass grafting was performed in 6 patients. Transthoracic echocardiography was performed at baseline, at discharge, at 4 to 6 months, at 11 to 14 months, and annually thereafter.ResultsValve implantation was successful in 30 patients. The procedure was converted to conventional aortic valve replacement in 2 patients. Mean bypass time was 111 ± 42 minutes, and crossclamp time was 70 ± 23 minutes. Valve implantation took 21 ± 7 minutes. The transvalvular gradients at discharge were 10 ± 3 mm Hg (mean) and 20 ± 7 mm Hg (peak), and the effective orifice area was 1.9 ± 0.4 cm(2). At 2-year follow-up, gradients were 7 ± 3 mm Hg (mean) and 14 ± 4 mm Hg (peak), and the effective orifice area was 1.9 ± 0.3 cm(2). There was no intraoperative mortality: Two patients died of causes unrelated to the valve during follow-up. One redo aortic valve replacement was performed at 22 months for prosthetic valve endocarditis.ConclusionsSutureless aortic valve replacement is feasible and safe with the Trilogy System. After an initial learning curve, the modular valve design allows a more rapid and simple implantation compared with conventional stented tissue valves. The simplicity may also facilitate a greater adoption of minimally invasive aortic valve replacement by a broader spectrum of surgeons.Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…