• J Neurosurg Spine · Oct 2006

    Comparative Study

    Biomechanical comparison of two new atlantoaxial fixation techniques with C1-2 transarticular screw-graft fixation.

    • Roger Härtl, Robert H Chamberlain, Mary S Fifield, Dean Chou, Volker K H Sonntag, and Neil R Crawford.
    • Spinal Biomechanics Laboratory, Division of Neurological Surgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona 85013, USA.
    • J Neurosurg Spine. 2006 Oct 1;5(4):336-42.

    ObjectTwo new techniques for atlantoaxial fixation have been recently described. In one technique, C-2 intralaminar screws are connected with C-1 lateral mass screws; in the second, C-1 and C-3 lateral mass screws are interconnected and C-2 is wired sublaminarly. Both techniques include a C1-2 interspinous graft. The authors compared these techniques with the gold-standard, interspinous graft-augmented C1-2 transarticular screw fixation and with a control C1-2 interspinous graft fixation procedure alone.MethodsIn six human cadaveric occiput-C4 specimens, nonconstraining 1.5-Nm pure moments were applied to induce flexion, extension, lateral bending, and axial rotation during which three-dimensional angular motion was measured optoelectronically. Each specimen was tested in the normal state, with graft alone (after odontoidectomy), and then in varying order after applying each construct with a rewired graft. All three constructs allowed significantly less angular motion at the C1-2 junction than the wired interspinous graft alone during lateral bending and axial rotation (p < 0.01, paired Student t-test) but not during flexion or extension. Transarticular screw fixation with an interspinous graft allowed less motion at the atlantoaxial junction than the two new constructs in several conditions. Differences were greater between the transarticular screw construct and the intralaminar screw construct than between the transarticular screw construct and the C1-3 lateral mass screw construct. During lateral bending and axial rotation, the C1-3 construct allowed less motion at the atlantoaxial junction than the intralaminar screw construct.ConclusionsBiomechanically, the gold-standard C1-2 transarticular screw fixation outperformed the two new techniques during lateral bending and axial rotation. Wiring C-2 to C1-3 rods provided greater stability than C1-2 laminar screws, but it sacrificed C2-3 mobility. It is unknown whether the small differences observed biomechanically would lead to clinically relevant differences in fusion rates.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.