Critical care medicine · Mar 1992
Comparative StudyContinuous measurement of cardiac output by the Fick principle: clinical validation in intensive care.
- O Keinänen, J Takala, and A Kari.
- Department of Intensive Care, Kuopio University Hospital, Finland.
- Crit. Care Med. 1992 Mar 1;20(3):360-5.
ObjectiveTo compare continuous measurement of cardiac output by the Fick principle with the thermodilution cardiac output technique in hemodynamically unstable patients.DesignAn open comparison of two methods.SettingMultidisciplinary ICU in a university hospital.PatientsEight patients after coronary bypass surgery and 13 patients with hyperdynamic septic shock. All patients were mechanically ventilated.Measurements And Main ResultsThe continuous Fick cardiac output technique was compared with the thermodilution cardiac output using both warm and cold injection in the coronary artery bypass surgery patients and using warm injection only in the patients with hyperdynamic septic shock. The mean difference between the continuous cardiac output technique and all thermodilution measurements (n = 201) was 0.6 +/- 19%. There was a good correlation between the continuous cardiac output and the warm thermodilution technique (n = 125, r2 = .79; p less than .001). When consecutive measurements with warm and cold thermodilution were compared with the respective Fick-derived values (n = 76), the mean differences between the Fick-derived and the warm and cold thermodilution cardiac output values were 0.2 +/- 1.0 L/min and 0.3 +/- 1.0 L/min, respectively. The relationship between Fick-derived and both methods of thermodilution-derived cardiac output was relatively constant during different modes of ventilatory support. The correlation between the thermodilution measurements with cold and room temperature injectate was weak (r2 = .36; p less than .001), whereas a good correlation was observed between the respective Fick-derived values (r2 = .73; p less than .001). The mean difference between the warm and cold thermodilution cardiac output measurements was 0.1 +/- 1.1 L/min and between the corresponding Fick-derived measurements was 0.01 +/- 0.7 L/min.ConclusionsContinuous measurement of cardiac output by the Fick principle offers a convenient, reproducible method for hemodynamic monitoring of unstable patients. The variation between the two tested thermodilution techniques is likely to reflect relatively rapid dynamic variation of cardiac output, which is filtered in the 1-min average of cardiac output obtained by the continuous Fick technique.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.