• Diabetes Technol. Ther. · Jan 2001

    Comparative Study

    A novel method for continuous online glucose monitoring in humans: the comparative microdialysis technique.

    • U Hoss, B Kalatz, R Gessler, H J Pfleiderer, E Andreis, M Rutschmann, H Rinne, M Schoemaker, C Haug, and R D Fussgaenger.
    • Institute of Diabetes Technology at the University of Ulm, Germany. udoh@minimed.com
    • Diabetes Technol. Ther. 2001 Jan 1;3(2):237-43.

    AbstractThe aim of this study was to prove the feasibility of continuous subcutaneous glucose monitoring in humans using the comparative microdialysis technique (CMT). The performance of the CMT was determined by comparing tissue glucose values with venous or capillary blood glucose values in healthy volunteers and type 1 diabetic subjects. The CMT is a microdialysis-based system for continuous online glucose monitoring in humans. This technique does not require calibration by the patient. Physiological saline with glucose (5.5 mM) is pumped in a stop-flow mode through a microdialysis probe inserted into the abdominal s.c. tissue. Tissue glucose concentration is calculated by comparing the dialysate and perfusate glucose concentrations. The time delay due to the measurement process is 9 min. We tested the CMT on six healthy volunteers and six type 1 diabetic patients for 24 h in our clinical setting. Comparisons were made to HemoCue analyzer (Angelholm, Sweden) capillary blood glucose measurements (healthy volunteers) and to venous blood glucose concentration determined with a Hitachi analyzer (diabetic patients). The mean absolute relative error of the CMT glucose values from the blood glucose values was 17.8+/-15.5% (n = 167) for the healthy volunteers and 11.0+/-10.8% (n = 425) for the diabetic patients. The mean difference was 0.42+/-1.06 mM (healthy volunteers) and -0.17+/-1.22 mM (diabetic patients). Error grid analysis for the values obtained in diabetic patients demonstrated that 99% of CMT glucose values were within clinically acceptable regions (regions A and B of the Clarke Error Grid). The study results show that the CMT is an accurate technique for continuous online glucose monitoring.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…