• Respiratory care · Mar 2013

    Randomized Controlled Trial

    Evaluation of recruited lung volume at inspiratory plateau pressure with PEEP using bedside digital chest X-ray in patients with acute lung injury/ARDS.

    • Florent Wallet, Bertrand Delannoy, Audrey Haquin, Sophie Debord, Véronique Leray, Gaël Bourdin, Frédérique Bayle, Jean-Christophe Richard, Loic Boussel, and Claude Guérin.
    • Medical ICU, Lyon, France.
    • Respir Care. 2013 Mar 1;58(3):416-23.

    BackgroundWe wanted to assess whether there was a significant relationship between recruited lung volume (V(rec)) and change in density on digital processed chest x-ray measured at 2 different levels of inspiratory plateau pressure corresponding to 2 PEEP levels in patients with acute lung injury or ARDS.MethodsIn 14 subjects, PEEP 5 cm H2O and 15 cm H2O were prospectively applied in a random order for 10 min. At the end of each period, chest x-ray was taken using a digital portable device, and a pressure-volume curve of the respiratory system was performed. We also assessed P(aO2), and the static and the dynamic (C(dyn,rs)) compliance of the respiratory system. Change in end-expiratory lung volume between tidal breath and relaxation volume of the respiratory system was determined. Radiological attenuation was measured on chest x-rays in 4 regions of interest in the right lung, and in 3 regions of interest in the left lung, drawn in posterior intercostal spaces from top to bottom, by using dedicated software. The ratio of lung density in each region between PEEP 15 and PEEP 5 (rP15/P5) and their arithmetic mean (μP15/P5) were computed. V(rec) was determined from the pressure-volume curves.ResultsThe median value of rP15/P5 in the 98 lung levels was 0.91 (0.80-1.01), which was significantly different from 1 (P < .001). The values of rP15/P5 were not significantly different between the lung levels. The median values of V(rec) and μP15/P5 were 288 (173-402) mL and 0.90 (0.80-0.97), respectively. There was a significant negative correlation between V(rec) and μP15/P5 (R = -0.77, P = .01). The reduction in μP15/P5 tended to correlate with the increase in C(dyn,rs) (R = -0.49, P = .077) or in P(aO2) (R = -0.53, P = .05) between PEEP 15 cm H2O and PEEP 5 cm H2O.ConclusionsDigital chest x-ray done at the bedside in acute lung injury/ARDS subjects was able to detect a reduction in density between PEEP 5 cm H2O and PEEP 15 cm H2O, which correlated with V(rec).

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.