-
Comparative Study
Mechanical behaviors of Flutter VRP1, Shaker, and Acapella devices.
- Alexandre Pereira dos Santos, Rogério Contato Guimarães, Eliane Maria de Carvalho, and Ada Clarice Gastaldi.
- Departamento de Fisioterapia, Associação Salgado de Oliveira, Institutos Superiores de Ensino do Censa, Campos dos Goytacazes, Rio de Janeiro, Brazil.
- Respir Care. 2013 Feb 1;58(2):298-304.
BackgroundFlutter VRP1, Shaker, and Acapella are devices that combine positive expiratory pressure (PEP) and oscillations.ObjectivesTo compare the mechanical performance of the Flutter VRP1, Shaker, and Acapella devices.MethodsAn experimental platform and a ventilator, used a flow generator at 5, 10, 15, 20, 26, and 32 L/min, were employed at angles of -30°, 0°, and +30° to evaluate Flutter VRP1 and Shaker, whereas Acapella was adjusted at intermediate, higher, and lower levels of resistance, including positive expiratory pressures (PEP) along with air outflow rates and oscillation frequencies.ResultsWhen the relationships between pressure amplitudes of all air flows were analyzed for the 3 devices at low and intermediate pressures levels, no statistically significant differences were observed in mean pressure amplitudes between Flutter VRP1 and Shaker devices. However, both devices had different values from Acapella, with their pressure amplitude values being higher than that of Acapella (P = .04). There were no statistically significant differences in PEP for the 3 angles or marks regarding all air flows. The expected relationships between variables were observed, with increases in PEP, compared to those of air flows and resistance. Nevertheless, there was a statistically significant difference in frequency of oscillation between these devices and Acapella, whose value was higher than those of Flutter VRP1 and Shaker devices (P = .002). At intermediate pressure levels, the patterns were the same, in comparison to low pressures, although the Acapella device showed frequencies of oscillation values lower than those of Flutter VRP1 and Shaker (P < .001). At high pressures, there were no statistically significant differences among the 3 devices for frequency of oscillations.ConclusionsThe Flutter VRP1 and Shaker devices had a similar performance to that of Acapella in many aspects, except for PEP.© 2013 Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.