    Reliability of airway occlusion pressure as an index of respiratory motor output.

    • Takeshi Kera, Akiko Aihara, and Takashi Inomata.
    • Department of Physical Therapy, Nihon Institute of Medical Science, Saitama, Japan. kera@nims.ac.jp
    • Respir Care. 2013 May 1;58(5):845-9.

    BackgroundAirway occlusion pressure 0.1 s after the start of inspiratory flow (P0.1) is used as an index of respiratory motor output; however, the reliability of P0.1 in this capacity has not been sufficiently investigated. Therefore, the aim of our study was to examine the reliability of P0.1.MethodsEleven healthy subjects (7 men and 4 women) participated in our study. Subjects were placed in a supine position, and P0.1 was measured every 30 s for 5 min, following a 1-min period during which ventilation and breathing frequency were measured. A total of 10 P0.1 values were obtained, and the intraclass correlation coefficient (ICC) was used to analyze reliability. ICC values from ICC (1, 2) to ICC (1, 10) were calculated following a number of measurements (k), where ICC (1, k) was increased sequentially from 2 to 10.ResultsThe ICC (1, 2) through ICC (1, 10) values were found to be between 0.877 and 0.960 (95% CI 0.565-0.966 and 0.912-0.987, respectively). When the target coefficient was set at 0.9, the ICC (1, 1) from 10 measurements was calculated a minimum of 4 times.ConclusionsAlthough a single measurement of P0.1 was somewhat reliable, the 95% CIs indicated that it is necessary to determine the average value of 3 or more measurements. The minimum of 4 repeat measurements were required to obtain valid results, indicating that the current method of determining P0.1 by averaging the values from at least 4 repeated measurements is valid.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…