• Eur J Anaesthesiol · Jan 2006

    Comparative Study

    Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model.

    • J Bajorat, R Hofmockel, D A Vagts, M Janda, B Pohl, C Beck, and G Noeldge-Schomburg.
    • University of Rostock, School of Medicine, Department of Anaesthesiology and Intensive Care Medicine, Germany. joern.bajorat@web.de
    • Eur J Anaesthesiol. 2006 Jan 1;23(1):23-30.

    Background And ObjectiveDespite the introduction of various less-invasive concepts of cardiac output measurement, pulmonary arterial thermodilution is still the most common measurement technique.MethodsThis prospective controlled study was designed to compare different methods of cardiac output measurement simultaneously. Pulmonary arterial thermodilution, transpulmonary thermodilution (PiCCO), trans-oesophageal echo-Doppler probe (HemoSonic) and partial carbon dioxide rebreathing technique (NICO monitor) were evaluated against a peri-aortic transit-time flow-probe as reference method in a clinically relevant animal model. After approval from the Local Ethics Committee on Animal Research, the investigations were conducted in nine anesthetized domestic pigs. Systemic haemodynamics were modulated systematically by the application of catecholamines, caval occlusion and exsanguination. Statistical analysis was performed with Bland-Altman and linear regression.ResultsA total of 366 paired cardiac output measurements were carried out at a reference cardiac output between 0.5 and 7 L min(-1). The correlation coefficients for pulmonary arterial and transpulmonary thermodilution against reference were 0.93 and 0.95, for trans-oesophageal Doppler and partial rebreathing technique 0.84 and 0.77. Pulmonary arterial thermodilution and transpulmonary thermodilution showed comparable bias and limits of agreement. Where HemoSonic showed an overestimation of cardiac output at a higher precision, NICO overestimated low and underestimated higher cardiac output values.ConclusionsOur data suggest that pulmonary arterial thermodilution and PiCCO may be interchangeably used for cardiac output measurement even under acute haemodynamic changes. The method described by Bland and Altman demonstrated an overestimation of cardiac output for both thermodilution methods. HemoSonic and NICO offer non-invasive alternatives and complementary monitoring tools in numerous clinical situations. Trend monitoring and haemodynamic optimizing can be applied sufficiently, when absolute measures are judged critically in a clinical context. The use of the NICO system seems to be limited during acute circulatory changes.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.