• Investigative radiology · Sep 2009

    Comparative Study

    A comparison of 3T and 7T in the detection of small parenchymal veins within MS lesions.

    • Emma C Tallantyre, Paul S Morgan, Jennifer E Dixon, Ali Al-Radaideh, Matthew J Brookes, Nikos Evangelou, and Peter G Morris.
    • Department of Clinical Neurology, Medical School, University of Nottingham, Nottingham, United Kingdom.
    • Invest Radiol. 2009 Sep 1;44(9):491-4.

    ObjectiveHistologic examination of multiple sclerosis (MS) brain lesions reveals heterogeneity including the presence or absence of a central blood vessel. Recent work has shown that T2* weighted magnetic resonance imaging at 7T allows the identification of small parenchymal veins within MS lesions. The aims of this study were (1) to compare whether a comparable sequence at 3T was also capable of demonstrating parenchymal veins within MS brain lesions, and (2) to investigate the potential of 7T T2* weighted imaging to differentiate between MS white matter lesions and age-related vascular lesions seen in controls.Materials And MethodsSeven patients with demyelinating brain disease and 7 healthy volunteers were scanned at 3T and 7T. Fluid attenuated inversion recovery (FLAIR) images acquired at 3T were used to identify each brain lesion in each patient. A comparison of images from both field strengths was then made to determine whether white matter lesions seen in 3T FLAIR images could be identified in T2*-weighted images, and whether a central vein could be detected.ResultsA total of 358 brain lesions were identified in the brains of the 7 patients using 3T FLAIR images. The 3T T2* sequence detected 89% of FLAIR lesions compared with 94% using the 7T T2* sequence (P = 0.0002). A central vessel could be identified in 45% of visible lesions using 3T T2* and 87% of visible lesions using 7T T2* (P < 0.0001). Using 7T T2* imaging, a central vein was evident in only 8% of the discrete white matter lesions found in the brains of healthy volunteers.DiscussionThis study suggests that ultra high field imaging is advantageous in demonstrating detailed structural anatomy of MS lesions. 7T T2* imaging can be used in the future to investigate the pathogenesis of MS lesions. The potential for ultra high field imaging to discriminate between MS white matter lesions and microangiopathic lesions warrants further investigation as this would represent a clinically useful application.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…