• Respiratory care · Mar 2014

    Apnea testing: the effects of insufflation catheter size and flow rate on pressure and volume within a test lung.

    • Nicholas R Henry and S Gregory Marshall.
    • Department of Respiratory Care, Texas State University, San Marcos, Texas.
    • Respir Care. 2014 Mar 1;59(3):406-10.

    BackgroundThe apnea test is used to determine the absence of respiratory drive when determining brain death. Current guidelines for performing the apnea test do not specify the size of insufflation catheter (IC) to use with each endotracheal tube (ETT) size, despite case reports describing procedure-related complications with the use of various IC sizes. We studied the effect of the ratio of IC outer diameter to ETT inner diameter on the pressure and volume generated within the lungs during the apnea test.MethodsWe tested ETTs with inner diameters of 6.0-10.0 mm, IC outer diameters of 10-16 French, and oxygen-supply tubing, at oxygen flows of 6-15 L/min, in an intubation manikin connected to a test lung.ResultsThe multivariate analysis of variance method identified significant differences in the pressures and volumes during the apnea test (P < .001), and the Tukey method identified significant differences in the pressures and volumes associated with IC/ETT ratios ≥ 0.7 and < 0.7 (P < .05).ConclusionsAn IC with an outer diameter < 70% of the ETT inner diameter, at 6 L/min, may prevent inappropriate lung pressure and volume during the apnea test. This recommendation, coupled with current American Academy of Neurology guidelines for the determination of brain death, may reduce the risk of procedure-related complications.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.