-
Arch Phys Med Rehabil · Nov 2008
Multicenter Study Comparative StudyPerformance-based or self-report measures of physical function: which should be used in clinical trials of hip fracture patients?
- Nancy K Latham, Vinay Mehta, Allison Martin Nguyen, Alan M Jette, Sippy Olarsch, Dimitris Papanicolaou, and Julie Chandler.
- Health and Disability Research Unit, Boston University School of Public Health, Boston, MA 02118-2639, USA. nlatham@bu.edu
- Arch Phys Med Rehabil. 2008 Nov 1;89(11):2146-55.
ObjectivesTo assess the validity, sensitivity to change, and responsiveness of 3 self-report and 4 performance-based measures of physical function: activity measure for postacute care (AM-PAC) Physical Mobility and Personal Care scales, the Medical Outcomes Study 36-Item Short Form Health Survey Physical Function scale (SF-36 PF), the Physical Functional Performance test (PFP-10), the Short Physical Performance Battery (SPPB), a 4-meter gait speed, and the six-minute walk test (6MWT).DesignA prospective observational study of patients after a hip fracture. Assessments were performed at baseline and 12 weeks postenrollment.SettingInpatient and outpatient rehabilitation facilities in Norway, the United Kingdom, Sweden, Israel, Germany, the United States, Denmark, and Spain.ParticipantsA sample of study participants (N=108) who had a hip fracture.InterventionsNot applicable.Main Outcome MeasuresAssessments of validity (known-groups, concurrent, construct, and predictive), sensitivity to change (effect size, standardized response mean [SRM], SE of measure, minimal detectable change (MDC), and responsiveness (optimal operating cut-points and area under the curve) between baseline and 12-week follow-up.ResultsAll physical function measures achieved comparably acceptable levels of validity. Odds ratios in predicting patient Global Assessment of Improvement at 12 weeks were as follows: AM-PAC Physical Mobility scale, 5.3; AM-PAC Personal Care scale, 3.6; SF-36 PF, 4.3; SPPB, 2.0; PFP-10, 2.5; gait speed, 1.9; and 6MWT, 2.4. Effect sizes and SRM exceeded 1 SD for all 7 measures. Percent of patients who exceeded the MDC(90) at week 12 were as follows: AM-PAC Physical Mobility scale, 90%; AM-PAC Personal Care scale, 74%; SF-36 PF, 66%; SPPB, 36%; PFP-10, 75%; gait speed, 69%; and 6MWT, 75%. When evaluating responsiveness using the area under receiver operating curves for each measure, all measures had acceptable responsiveness, and no pattern emerged of superior responsiveness depending on the type of measure used.ConclusionsFindings reveal that the validity, sensitivity, and responsiveness of self-report measures of physical function are comparable to performance-based measures in a sample of patients followed after fracturing a hip. From a psychometric perspective, either type of functional measure would be suitable for use in clinical trials where improvement in function is an endpoint of interest. The selection of the most appropriate type of functional measure as the primary endpoint for a clinical trial will depend on other factors, such as the measure's feasibility or the strength of the association between the hypothesized mechanism of action of the study intervention and a functional outcome measure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.