• Interact Cardiovasc Thorac Surg · Dec 2011

    Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences.

    • Calogera Pisano, Teresa D'Amico, Cesira Palmeri, Rosalba Franchino, Khalil Fattouch, Giuseppe Bianco, and Giovanni Ruvolo.
    • Department of Cardiac Surgery, Faculty of Medicine, University of Palermo, Palermo, Italy. bacalipi@libero.it
    • Interact Cardiovasc Thorac Surg. 2011 Dec 1;13(6):606-10.

    ObjectivesThe purpose is to evaluate in vivo at rest and under stress conditions hemodynamic performance of the small size St. Jude Medical Regent (SJMR) prosthetic valve in patients with a body surface area (BSA) of 1.8 ± 0.11 m(2) and to define the role of valve prosthesis- patient mismatch on left ventricular mass regression following aortic valve replacement.MethodsWe evaluated 25 cases (12 males and 13 females, mean age 65.2 ± 8 years) of aortic valve replacement (17 mm SJMR in three cases and 19 mm SJMR in 22 cases). All the patients underwent at rest Doppler echocardiography before and after surgery and both basal and dobutamine stress echocardiography (DSE) at follow-up. The mean duration of follow-up was 41.3 ± 24 months.ResultsA significant reduction in mean and peak transaortic gradients and peak transaortic velocity over time following valve replacement has been identified. After surgery, there was a significant increase of ejection fraction. DSE significantly increased heart rate, ejection fraction, peak transaortic gradient and peak transaortic velocity. All patients passed DSE without complication. Even if a significant mismatch was present in 76% of cases, the left ventricular mass decreased significantly from preoperative value of 278.7 ± 51.1 g to 181.5 ± 52.73 g, respectively.ConclusionAortic valve replacement with 17 mm SJMR or 19 mm SJMR prostheses appear to provide satisfactory clinical and hemodynamic results at rest and under DSE, even in those patients with BSA of 1.8 ± 0.11 m(2) where it was not possible to enlarge the aortic annulus. Prosthesis-patient mismatch is not associated with lesser regression of left ventricular mass. Dobutamine stress echocardiography should be a useful and effective means for evaluating prosthesis hemodynamic aspects.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.