• J Spinal Disord Tech · Jul 2007

    Case Reports

    Using intraoperative electrophysiologic monitoring as a diagnostic tool for determining levels to decompress in the cervical spine: a case report.

    • James L Chappuis and Gregory Johnson.
    • Orthopaedic and Spine Surgery of Atlanta LLC, Atlanta, GA 30327, USA. jlchappuis@aol.com
    • J Spinal Disord Tech. 2007 Jul 1;20(5):403-7.

    ObjectiveThis report describes the clinical usefulness of using intraoperative electrophysiologic monitoring as a diagnostic tool for determining levels to decompress in the cervical spine.MethodsA 59-year-old man was experiencing intractable neck and left upper extremity pain after sustaining a second spinal injury. (The patient had previously undergone an anterior cervical discectomy and fusion at C5-C6 with plating to treat injuries from a motor vehicle accident.) On examination, he had no motor changes but did have pain in his left upper extremity and numbness of the left thumb and index finger. A myelogram and postmyelogram computed tomography scan revealed a disc herniation at C4-C5 with severe neural foraminal disease on the left side of C4-C5 and residual posterior osteophytes with questionable neuroforaminal stenosis on the left side of C5-C6. Routine electrophysiologic studies showed mild irritation of the left biceps (left C5-C6 nerve root), indicating radiculopathy. The patient was admitted with plans to undergo plate removal, exploration of the fusion at C5-C6, and an anterior cervical discectomy with foraminotomies and fusion at C4-C5. Continuous free-running electromyography was recorded during the surgical procedures.ResultsThe surgery was performed as planned; however, the irritation observed at C5-C6 did not subside. Relying on this information, as an extension of the patient's history and physical examination, a decision was made to remove the previous fusion at C5-C6 and to explore the left C6 root. A very tight neural foramen was found at this level. After decompression and foraminotomy, no electrophysiologic activity above baseline was recorded at C5-C6. The patient was then fused and plated from C4 to C6, and awoke with no left upper extremity pain. Neurologic examination was normal immediately after surgery and at 3 months follow-up.ConclusionsIntraoperative, continuous free-running electromyography proved clinically effective in determining the course of surgery.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.