-
Randomized Controlled Trial Comparative Study Clinical Trial
Low- and medium-molecular-weight hydroxyethyl starches: comparison of their effect on blood coagulation.
- M Jamnicki, T Bombeli, B Seifert, A Zollinger, V Camenzind, T Pasch, and D R Spahn.
- Institute of Anesthesiology, University Hospital, Zurich, Switzerland.
- Anesthesiology. 2000 Nov 1;93(5):1231-7.
BackgroundHigh-molecular-weight hydroxyethyl starch (HES) compromises blood coagulation more than medium-molecular-weight HES. The authors compared medium molecular weight HES (200 kd [HES200]) and low-molecular-weight HES (70 kd [HES70]).MethodsIn a prospective, double-blind, randomized-sequence crossover study, 22 male volunteers received 15 ml/kg HES200 and HES70. Blood samples were taken before and 5 min, 30 min, 1 h, 2 h, 4 h, 8 h, and 24 h after infusion. The following parameters were analyzed at all time points: prothrombin time, activated partial thromboplastin time, fibrinogen, factor VIII, antigenetic and functional von Willebrand factor, platelets, Thrombelastograph analysis parameters (reaction time, coagulation time, maximum amplitude, angle alpha, and clot lysis 30 and 60 min after maximum amplitude), ionized calcium, hematocrit, HES plasma concentration, molecular weight (weight average and number average), molar substitution, and polydispersity (weight average/number average). Repeated-measures analysis of variance (P < 0.05) was used to compare the response of the aforementioned parameters to the infusion of HES70 and HES200.ResultsBoth HES solutions had a significant impact on all parameters. A slightly greater compromise with HES200 was found in activated partial thromboplastin time (P = 0.010), factor VIII (P = 0.009), antigenetic von Willebrand factor (P = 0.041), functional von Willebrand factor (P = 0.026), maximum amplitude (P = 0.008), and angle alpha (P = 0.003). No difference was established with the other parameters. HES concentration (P < 0.001), weight average (P < 0.001), number average (P < 0.001), and polydispersity (P < 0.001) were higher with HES200. There was no difference with molar substitution (P = 0.091).ConclusionsLow-molecular-weight hydroxyethyl starch (70 kd) compromises blood coagulation slightly less than HES200, but it is unclear whether this is clinically relevant.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.