-
Eur J Cardiothorac Surg · Oct 2011
Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery?
- Mario de Bellis, Rosanna Accardo, Massimo Di Maio, Carmine La Manna, Carmine Lamanna, Giovanni Battista Rossi, Maria Caterina Pace, Vincenzo Romano, and Gaetano Rocco.
- Department of Anesthesia and Intensive Care, Second University of Naples, Naples, Italy.
- Eur J Cardiothorac Surg. 2011 Oct 1;40(4):912-6.
ObjectivesFlexible bronchoscopy is recommended to confirm correct placement of double-lumen tubes used for thoracic anesthesia. However, there is still controversy over routine bronchoscopic confirmation of their position. This study aimed to verify the usefulness of flexible bronchoscopy for confirming the position of double-lumen tubes after blind intubation.MethodsDuring a 9-month period, consecutive patients undergoing elective oncologic thoracic surgery were prospectively enrolled in the study. All patients were intubated with a left disposable polyvinyl chloride double-lumen tube. Immediately after intubation, clinical verification was made by the anesthesiologist. Then, the endoscopist performed flexible bronchoscopy with a 2.8-mm diameter Olympus(®) video bronchoscope, and verified the position of the double-lumen tube, before positioning the patient. The double-lumen tube was in optimal position, if the bronchial cuff was immediately below the tracheal carina, and there was a clear view of the left subcarina, with unobstructed left upper and lower bronchi. Misplacement of the double-lumen tube was diagnosed when the tube had to be moved (in or out) for more than 0.5 cm to correct its position. Critical malposition meant a double-lumen tube dislocated in the trachea or in the right bronchi, requiring immediate re-intubation under bronchoscopic guidance.ResultsA total of 144 patients (44 women (42%) and 60 men (58%), with a mean age of 51 years (range 25-77 years)) were enrolled in the study. Surgical procedures included 37 right-sided and 31 left-sided thoracotomies, 22 video-assisted thoracoscopic surgeries (VATSs) (16 right-sided and six left-sided), one median sternotomy, six mediastinotomies, and seven miscellaneous procedures. In 66 (63%, 95% confidence interval 53.2-71.8%) cases, there was complete agreement between the anesthesiologist and the endoscopist. The latter diagnosed misplacement of the double-lumen tube in 33 (32%, 95% confidence interval 22.8-40.7%) patients and critical malposition in five (5%, 95% confidence interval 0.7-8.9%) cases.ConclusionsAfter blind intubation, 37% of double-lumen tubes required repositioning by means of flexible bronchoscopy, despite positive evaluation made by the anesthesiologist. Our data suggests that initial bronchoscopic assessment should be made with the patient still in the supine position, and confirms that flexible bronchoscopy is useful in verifying the correct position of double-lumen tubes or adjusting possible misplacements, before starting thoracic surgery.Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.