• J Neurointerv Surg · Aug 2016

    Case Reports

    Intra-DIC (distal intracranial catheter) deployment of the Pipeline embolization device: a novel rescue strategy for failed device expansion.

    • Li-Mei Lin, Geoffrey P Colby, Bowen Jiang, Neelesh Nundkumar, Judy Huang, Rafael J Tamargo, and Alexander L Coon.
    • Department of Neurosurgery, University of California, Irvine School of Medicine, UC Irvine Medical Center, Orange, California, USA.
    • J Neurointerv Surg. 2016 Aug 1; 8 (8): 840-6.

    BackgroundThe Pipeline embolization device (PED) is a braided flow diverter that requires a combination of meticulous maneuvers to assure proper device opening and expansion. Mechanical, anatomical, or technical challenges can result in a partially deployed PED with failed expansion.ObjectiveTo present a new alternative method of PED deployment using the Navien distal intracranial catheter (DIC) as a salvage maneuver for cases where PED opening fails with standard techniques.MethodsWe retrospectively reviewed a prospective, single-center aneurysm database to identify all patients who underwent endovascular treatment of intracranial aneurysms using the PED with the Navien distal intracranial catheter access platform. Cases requiring PED deployment within the Navien catheter were reviewed. Data was collected for patient demographics, aneurysm characteristics, and technical details of the interventional procedure.ResultsEleven PED neurointerventions requiring intra-Navien PED deployment to fully open the PED were identified. Mean patient age was 55.5±9.9 years (range 37-76 years). Mean aneurysm size was 12.5 mm±4.9 mm (range 2-42 mm). All aneurysms were located in the anterior circulation (anterior cerebral artery, n=1; supraclinoid, n=1; ophthalmic/paraophthalmic, n=6; cavernous, n=3; petrocervical, n=1). Mean fluoroscopy time was 67.1±20.5 min. The intra-Navien technique was used to open the proximal PED (n=7) and the mid-portion (n=4). Post-processing of the PED with a balloon was used in six cases.ConclusionsWhen a partially deployed PED remains constrained despite exhaustion of standard maneuvers to facilitate opening, the technique of intra-Navien PED deployment is a valuable rescue strategy. This new alternative method of PED deployment can be used to open a stretched device with successful completion of the PED implantation.Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…