• J Trauma · Oct 2011

    The efficacy of spontaneous and controlled ventilation with various cricothyrotomy devices: a quantitative in vitro assessment in a model lung.

    • Andrea Michalek-Sauberer, Marcus Granegger, and Hermann Gilly.
    • Department of Special Anaesthesia and Pain Therapy, Medical University of Vienna, Vienna General Hospital, Vienna, Austria. andrea.michalek-sauberer@meduniwien.ac.at
    • J Trauma. 2011 Oct 1;71(4):886-92.

    BackgroundGuidelines for the management of a difficult airway recommend performing a cricothyrotomy in a "can't intubate/can't ventilate" situation. We investigated the tidal volumes delivered by controlled and spontaneous ventilation by seven commercially available cricothyrotomy sets (cuffed: Quicktrach II, Portex Cricothyroidotomy Kit, and Melker cuffed cannula and uncuffed: Airfree, 4.0-mm ID Quicktrach, 6.0-mm inner diameter Melker, and 13-gauge Ravussin cannula) and two improvised devices (14-gauge intravenous cannula and spike and drip chamber device).MethodsA LS800 model lung, set at different values for compliance and resistance and modified with different upper airway diameter, was ventilated via the respective cricothyrotomy device mechanically and using a self-inflating bag. With the 13-gauge Ravussin cannula and the 14-gauge intravenous cannula, a Manujet injector was used for jet ventilation. Spontaneous ventilation was simulated with a Michigan 560i lung.ResultsDuring controlled or manual ventilation, all cuffed cricothyrotomy devices yielded adequate tidal volumes. Uncuffed devices provided tidal volumes≥300 mL only with an upper airway diameter of ≤3 mm. With a Manujet injector, adequate tidal volumes required an upper airway diameter between 3 mm and 5 mm. A spike and drip chamber device does not provide suitable emergency airway access. Spontaneous ventilation at adequate inspiratory pressure levels required a device inner diameter of at least 4 mm.ConclusionAs expected, cuffed cricothyrotomy devices yield the best results during controlled, manual, and spontaneous ventilation. With uncuffed cricothyrotomy devices, ventilation becomes ineffective when the upper airway obstruction allows for an upper airway diameter>3 mm.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.