• J Orthop Trauma · Sep 2013

    Biomechanical evaluation of interlocking lag screw design in intramedullary nailing of unstable pertrochanteric fractures.

    • Stefanie Hoffmann, Robert Paetzold, Daniel Stephan, Klaus Püschel, Volker Buehren, and Peter Augat.
    • Institute of Biomechanics, Trauma Center Murnau, Murnau, Germany. stefanie.hofffmann@bgu-murnau.de
    • J Orthop Trauma. 2013 Sep 1;27(9):483-90.

    ObjectivesIntramedullary nails with special lag screw designs may provide improved mechanical performance and alleviate clinical problems. We hypothesize that the proximal design of trochanteric nails affects mechanical performance.MethodsTen pairs of human cadaveric femora were implanted with 2 different short intramedullary nails without (Gamma3) and with an interlocking lag screw (Intertan). An unstable, multifragmentary, pertrochanteric fracture was created. Bones were tested in a cyclic testing protocol with increasing loads until failure simulating 1 leg stance. Stiffness, failure load, cycles to failure, and fracture gap movements were measured.ResultsInitially stiffness of the interlocking lag screw nail was almost 40% larger (P = 0.005) compared with the noninterlocking nail. During the test, the difference in stiffness gradually decreased. Failure load (13%, P = 0.02) and cycles to failure (18%, P = 0.02) were larger for the interlocking nail construct. Rotation and varus collapse of the head were initially up to 84% lower (P = 0.013) for the interlocking technique. During the test, the rate of rotational instability gradually increased for both techniques.ConclusionsThe interlocking lag screw design reduced movement of the femoral head and relative movement between fracture fragments. Beyond that the trapezoidal nail design of the Intertan reduced toggling within the trochanteric area and prolonged survival. Although this study showed a decrease in the retention of stability over time, failure did not occur until the equivalent of 2-3 months of reduced physical activity in which healing may have occurred under normal clinical conditions.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…