• Spine J · Jul 2009

    Lumbar intersegmental spacing and angulation in the modified lateral decubitus position versus variants of prone positioning.

    • Vijay Agarwal, Michael Wildstein, John B Tillman, William L Pelkey, and Todd F Alamin.
    • Department of Orthopaedic Surgery, Stanford University School of Medicine, CA 94305, USA.
    • Spine J. 2009 Jul 1;9(7):580-4.

    Background ContextInterspinous process devices represent an emerging treatment for neurogenic intermittent claudication resulting from lumbar spinal stenosis. Most published descriptions of the operative technique involve treatment of patients in the modified lateral decubitus knee-chest position (modified lateral decubitus), and yet many surgeons have begun to perform the procedure in various prone positions. The patient's positioning on the operating room table seems likely to influence resting interspinous distance, and thus implant sizing and possibly the risk of intraoperative spinous process fracture. The intersegmental lumbar effect of variants on operative prone positioning compared with the modified lateral decubitus position has not been studied.PurposeWe performed this study to determine the comparative differences in interspinous distance and intersegmental angulation effected by the lateral decubitus knee-chest position and the variants on prone positioning used in practice.Study Design/SettingExperimental human radiographic study.Patient SampleTwenty healthy male volunteers with a mean age of 43.6+/-10.8 years (range, 24-63), without chronic back pain, symptoms of neurogenic claudication, or history of lumbar surgery were enrolled.Outcome MeasuresInterspinous distance, anterior and posterior disc heights, disc angulation were measured on PACS monitor.MethodsLateral X-rays were taken of the lower lumbar spine in each of four different surgical positions (modified lateral decubitus, Andrews frame, Wilson frame, and Jackson frame). Statistical analysis was performed on the resultant data points to assess the significance of the effect of the position of the subject on intersegmental spacing and angulation.ResultsThe 20 enrollees had a mean age of 43.6+/-10.8 years (range, 24-63). The mean interspinous distance at the L4-L5 level was greatest on the Andrews table (23.5+/-8.3mm) followed by the modified lateral decubitus position (19.6+/-5.1mm), the Wilson frame (15.6+/-4.6mm), and then the Jackson frame (10.1+/-4.7mm; significantly less than all other positions p< or =.036). Mean segmental extension at the L4-L5 level was least in the modified lateral decubitus position (-0.1 degrees +/-2.9 degrees ); this was statistically similar to extension on the Andrews table (1.5 degrees +/-4.7 degrees , p=1.0), but significantly less than that recorded on the Wilson frame (4.6 degrees +/-3.1 degrees , p<.001), and also significantly less than that recorded on the Jackson frame (p< or =.001). Similar differences in segmental measurements were observed at L3-L4.ConclusionsProne positioning of patients in flexion on the operating table using the Andrews table or Wilson frame resulted in similar lumbar interspinous distance compared with the modified lateral decubitus position. Prone positioning on the Jackson frame resulted in statistically less interspinous distance than all other positions. Positioning on the Andrews table resulted in similar segmental angulation to the modified lateral decubitus position. Extrapolation from these data, obtained in healthy males younger than the typical age of patients treated with interspinous distraction devices, should clearly be done with caution. However, it seems reasonable to suggest that performing these procedures in the prone position using the Andrews table (greatest interspinous distance) is unlikely to result in the placement of significantly undersized implants, or significantly increase the force required to insert an implant.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.