J. Cardiothorac. Vasc. Anesth. · Dec 2002
Validation of continuous thermodilution cardiac output in patients implanted with a left ventricular assist device.
- B Mets, R J Frumento, E Bennett-Guerrero, and Y Naka.
- Department of Anesthesiology, Columbia University, New York, NY, USA.
- J. Cardiothorac. Vasc. Anesth. 2002 Dec 1;16(6):727-30.
ObjectiveTo assess the accuracy of a continuous cardiac output (CCO) monitor against an independent, intravascular measurement of flow as can be performed in patients fitted with a left ventricular assist device (LVAD).DesignA prospective cohort study.SettingAcademic tertiary-care center.ParticipantsAdult patients (n = 15) presenting for LVAD placement.InterventionsConsenting patients presenting for LVAD placement for end-stage cardiac failure were anesthetized, and a CCO pulmonary artery catheter was placed (OptiQ, CCO/SvO(2); Abbott Critical Care, North Chicago, IL). Patients were monitored with transesophageal echocardiography and excluded from analysis if aortic regurgitation was found. Cardiac output was determined using a Q-Vue, CCO/SvO(2) computer with digital readout (Abbott Critical Care, North Chicago, IL). The LVAD was placed in standard fashion during cardiopulmonary bypass. The Thoratec vented electric Heartmate (Thoratec Co, Pleasanton, CA) incorporates an LVAD flow console, which computes LVAD flow within +/- 5% (range, 1.8 to 10 L/min).Measurements And Main ResultsCardiac output flow measurements were made from both systems at the following time points: 5 minutes and 30 minutes after protamine administration, at chest closure, and after skin closure. Mean cardiac output for each device did not differ at any time point. Regression analysis (Pearson's) showed acceptable correlation (r(2) = 0.79, p < 0.0001), whereas a bias of 529 mL with limits of agreement of 1,208 mL were shown for CCO measurement compared with LVAD flow.ConclusionThe data indicate that the CCO system tends to overestimate cardiac output by approximately 500 mL/min when compared with LVAD flow. Nevertheless, this bias is within the range found by other less-invasive studies done to assess the accuracy of this system and further serves to confirm its relative accuracy.Copyright 2002, Elsevier Science (USA). All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.