Multicenter Study Comparative Study
Feasibility of noninvasive continuous finger arterial blood pressure measurements in very young children, aged 0-4 years.
- Peter Andriessen, Olaf Schraa, Wendy van Den Bosch-Ruis, Derk Jan Ten Harkel, Jos J Settels, Sidarto Bambang Oetomo, and Carlos E Blanco.
- Neonatal Intensive Care Unit, Máxima Medical Center, 5500 MB Veldhoven, The Netherlands. p.andriessen@mmc.nl
- Pediatr. Res. 2008 Jun 1;63(6):691-6.
AbstractOur goal was to study the feasibility of continuous noninvasive finger blood pressure (BP) monitoring in very young children, aged 0-4 y. To achieve this, we designed a set of small-sized finger cuffs based on the assessment of finger circumference. Finger arterial BP measured by a volume clamp device (Finapres technology) was compared with simultaneously measured intra-arterial BP in 15 very young children (median age, 5 mo; range, 0-48), admitted to the intensive care unit for vital monitoring. The finger cuff-derived BP waveforms showed good resemblance with the invasive arterial waveforms (mean root-mean-square error, 3 mm Hg). The correlation coefficient between both methods was 0.79 +/- 0.19 systolic and 0.74 +/- 0.24 diastolic. The correlation coefficient of beat-to-beat changes between both methods was 0.82 +/- 0.18 and 0.75 +/- 0.21, respectively. Three measurements were related to measurement errors (loose cuff application; wrong set-point). Excluding these erroneous measurements resulted in clinically acceptable measurement bias (-3.8 mm Hg) and 95% limits of agreement (-10.4 to + 2.8 mm Hg) of mean BP values. We conclude that continuous finger BP measurement is feasible in very young children. However, cuff application is critical, and the current set-point algorithm needs to be revised in very young children.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.