-
- Y K Kim, W J Shin, J G Song, I G Jun, H Y Kim, S H Seong, and G S Hwang.
- Asan Medical Center, University of Ulsan College of Medicine, 388-1 Pungnap 2dong, Song pa-gu, Seoul 138-736, South Korea. kshwang@amc.seoul.kr
- Transplant. Proc. 2009 Dec 1;41(10):4220-8.
BackgroundStroke volume variation (SVV) is being increasingly used to predict fluid responsiveness. Since radial arterial pressure (RAP) and femoral arterial pressure (FAP) frequently showing discrepancies during liver transplantation (LT), we sought to investigate the effect of differing arterial waveforms on SVV and cardiac output (CO) derived from the Vigileo device, by comparing SVV and CO values derived from RAP (SVV(RAP), CO(RAP)) and FAP (SVV(FAP), CO(FAP)) during LT.MethodsThe linear associations and agreements between SVV(RAP) and SVV(FAP) and between CO(RAP) and CO(FAP) were assessed during LT. Hemodynamic variables were measured at nine predefined time points in all 32 recipients, resulting in 288 data pairs.ResultsCorrelations were observed between SVV(RAP) and SVV(FAP) (r = .961) and between CO(RAP) and CO(FAP) (r = .848) at all time points. These correlations between SVV(RAP) and SVV(FAP) (r = .923) and between CO(RAP) and CO(FAP) (r = .902) existed even during the period when mean RAP and FAP values differed (10 minutes after reperfusion). Bland-Altman analysis for SVV(RAP) versus SVV(FAP) and for CO(RAP) versus CO(FAP) showed weak biases (-0.2% and -0.5 L/min) and reasonable limits of agreement (-2.2 to 1.8% and -1.9 to 0.9 L/min). The percentage errors for SVV and CO values were 27.0% and 22.2%.ConclusionsThere was no significant difference between SVV(RAP) and SVV(FAP) when measured using the Vigileo device during LT. This finding indicated that SVV obtained using the Vigileo device offered relatively consistent information regardless of the catheterization site.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.