• Vet Anaesth Analg · Mar 2016

    Evaluation of the non-calibrated pulse contour cardiac output monitor FloTrac/Vigileo against thermodilution in standing horses.

    • Annette P N Kutter, Regula Bettschart-Wolfensberger, Colin C Schwarzwald, Karine G Portier, and Simone K Ringer.
    • Section of Anaesthesiology, Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
    • Vet Anaesth Analg. 2016 Mar 1; 43 (2): 153-62.

    ObjectiveTo evaluate the non-calibrated, minimally invasive cardiac output (CO) monitor FloTrac/Vigileo (FloTrac) against thermodilution (TD) CO in standing horses.Study DesignProspective, experimental trial.AnimalsNine adult horses weighing a median (range) of 535 (470-602) kg.MethodsCatheters were placed in the right atrium, pulmonary artery and carotid artery under local anaesthesia. CO was measured 147 times by TD and FloTrac and indexed to body weight. Changes in CO were achieved with romifidine or xylazine and dobutamine constant rate infusions. Bland-Altman analysis, concordance and polar plot analysis were used to assess agreement and ability to track changes in CO.ResultsMean ± standard deviation COTD of 48 ± 16 mL kg(-1) minute(-1) (range: 19-93 mL kg(-1) minute(-1) ) and mean COF loTrac of 9 ± 3 mL kg(-1) minute(-1) (range: 5-21 mL kg(-1) minute(-1) ) were measured. Low agreement with a large mean bias of 39 mL kg(-1) minute(-1) and wide limits of agreement of 8-70 mL kg(-1) minute(-1) were found. The percentage error of 108% and precision of TD of ± 18% resulted in an estimated precision of FloTrac of ± 106%. Comparison of changes in COF loTrac with changes in COTD gave a concordance rate of 52% in the four-quadrant plot, and a mean polar angle of -11° with radial limits of agreement of ± 61 ° in the polar plot. Mean arterial pressure (MAP) and COF loTrac were positively correlated (r = 0.5, p < 0.0001). No correlation of MAP with COTD was observed.Conclusions And Clinical RelevanceThe FloTrac system, originally designed for use in humans, neither measured absolute CO in standing horses accurately nor tracked relative changes in CO measured by TD correctly. The false dependence of COF loTrac on arterial blood pressure further discourages the use of this technique in horses.© 2015 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…