J. Am. Coll. Cardiol. · Apr 2010
Multicenter StudyCombined heart failure device diagnostics identify patients at higher risk of subsequent heart failure hospitalizations: results from PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure) study.
- David J Whellan, Kevin T Ousdigian, Sana M Al-Khatib, Wenji Pu, Shantanu Sarkar, Charles B Porter, Behzad B Pavri, Christopher M O'Connor, and PARTNERS Study Investigators.
- Department of Medicine, Jefferson Medical College, 925 Chestnut Street, Philadelphia, PA 19107, USA. david.whellan@jefferson.edu
- J. Am. Coll. Cardiol. 2010 Apr 27;55(17):1803-10.
ObjectivesWe sought to determine the utility of combined heart failure (HF) device diagnostic information to predict clinical deterioration of HF in patients with systolic left ventricular dysfunction.BackgroundSome implantable devices continuously monitor HF device diagnostic information, but data are limited on the ability of combined HF device diagnostics to predict HF events.MethodsThe PARTNERS HF (Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure) was a prospective, multicenter observational study in patients receiving cardiac resynchronization therapy (CRT) implantable cardioverter-defibrillators. HF events were independently adjudicated. A combined HF device diagnostic algorithm was developed on an independent dataset. The algorithm was considered positive if a patient had 2 of the following abnormal criteria during a 1-month period: long atrial fibrillation duration, rapid ventricular rate during atrial fibrillation, high (> or =60) fluid index, low patient activity, abnormal autonomics (high night heart rate or low heart rate variability), or notable device therapy (low CRT pacing or implantable cardioverter-defibrillator shocks), or if they only had a very high (> or =100) fluid index. We used univariate and multivariable analyses to determine predictors of subsequent HF events within a month.ResultsWe analyzed data from 694 CRT defibrillator patients who were followed for 11.7 +/- 2 months. Ninety patients had 141 adjudicated HF hospitalizations with pulmonary congestion at least 60 days after implantation. Patients with a positive combined HF device diagnostics had a 5.5-fold increased risk of HF hospitalization with pulmonary signs or symptoms within the next month (hazard ratio: 5.5, 95% confidence interval: 3.4 to 8.8, p < 0.0001), and the risk remained high after adjusting for clinical variables (hazard ratio: 4.8, 95% confidence interval: 2.9 to 8.1, p < 0.0001).ConclusionsMonthly review of HF device diagnostic data identifies patients at a higher risk of HF hospitalizations within the subsequent month. (PARTNERS HF: Program to Access and Review Trending Information and Evaluate Correlation to Symptoms in Patients With Heart Failure; NCT00279955).Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.