    Evaluation of the Paratrend 7 intravascular blood gas monitor during cardiac surgery: comparison with the C4000 in-line blood gas monitor during cardiopulmonary bypass.

    • B Venkatesh, T H Clutton-Brock, and S P Hendry.
    • University Department of Anaesthesia and Intensive Care, Queen Elizabeth Hospital, University of Birmingham, UK.
    • J. Cardiothorac. Vasc. Anesth. 1995 Aug 1;9(4):412-9.

    ObjectiveTo evaluate the performance of the Paratrend 7 intravascular blood gas monitor (Biomedical Sensors, High Wycombe, UK, Ltd) during cardiac surgery and compare it with that of an in-line blood gas monitor placed in the arterial limb of an extracorporeal circuit during cardiopulmonary bypass.DesignA prospective study. Consecutive patient enrolment.SettingIn the cardiac surgical intensive care units at a tertiary referral center.InterventionInsertion of the Paratrend 7 intravascular sensor through the radial arterial catheter after induction of anesthesia.Measurements And Main ResultsSimultaneous measurements of pH, PCO2, and PO2 were made from the sensor and the blood gas analyzer, and the bias and precision were calculated on all the measured parameters. The bias and precision of the intravascular sensor during bypass for pH, PCO2, and PO2 were 0.01 and 0.06 pH units, 0.5 and 2.5 mmHg (2% and 8%), and 3 and 45 torr (0.5% and 14%), respectively. The bias and precision for the prebypass and the postbypass phases were comparable. The bias and precision of the extracorporeal monitor for pH, PCO2, and PO2 were 0.04 and 0.1 pH units, -0.3 and 4 mmHg (-1% and 15%) and 8 and 48 mmHg (4 and 18%), respectively. There were no instances of any complications attributable to the intravascular sensor.ConclusionsThe intravascular sensor used in this study functioned well during cardiopulmonary bypass and the postbypass phase. The performance of the intravascular sensor was better than the in-line blood gas monitor during cardiopulmonary bypass.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…