J Vasc Interv Radiol · Nov 2008
Embolic protection devices in patients with renal artery stenosis with chronic renal insufficiency: a clinical study.
- Sanjay Misra, Manuel T Gomes, Verghese Mathew, Gregory W Barsness, Stephen C Textor, Haraldur Bjarnason, and Michael A McKusick.
- Department of Radiology, Mayo Clinic College of Medicine, 200 First Street Southwest, Alfred 6460, Rochester, MN 55902, USA. misra.sanjay@mayo.edu
- J Vasc Interv Radiol. 2008 Nov 1;19(11):1639-45.
PurposeTo present clinical outcomes with the use of embolic protection devices (EPDs) and renal artery stents in patients with chronic renal insufficiency (CRI) and renal artery stenosis (RAS).Materials And MethodsA retrospective study was conducted in 23 patients with RAS and CRI who were treated with renal artery stent placement with an EPD. Follow-up data were obtained through medical records.ResultsIn 23 patients (18 men; 78%) with an average age of 69.4 years +/- 11 (range, 46-86 y), 32 renal arteries were treated for worsening renal function (n = 17; 74%) or uncontrolled hypertension and worsening renal function (n = 6; 26%). Nine FilterWire EZ devices were used in eight patients (35%) and 17 SpideRX devices were used in 15 patients (65%). The average follow-up was 8 months +/- 5. After the stent procedure, the mean systolic blood pressure decreased significantly (P < .05) whereas the diastolic pressure remained unchanged. There was a significant increase in the mean estimated glomerular filtration rate from 32.9 mL/min +/- 12.9 at baseline to 41.3 mL/min +/- 13.7 at last follow-up (P < .05). In 96% of patients, there was improvement or stabilization of kidney function. In six of the 17 SpideRX devices (35%), macroscopically evident embolic material was observed in the device after stent placement. There were two minor and two major complications.ConclusionsRenal artery stent placement combined with the use of a SpideRX or FilterWire EZ device is associated with an good clinical outcome with a reasonable safety profile.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.