• Pediatric pulmonology · Jan 1991

    Comparative Study

    Pulse oximetry versus measured arterial oxygen saturation: a comparison of the Nellcor N100 and the Biox III.

    • P Lebecque, P Shango, M Stijns, A Vliers, and A L Coates.
    • Cliniques St. Luc, Université Catholique de Louvain Bruxelles, Belgique.
    • Pediatr. Pulmonol. 1991 Jan 1;10(2):132-5.

    AbstractPulse oximetry is noninvasive, fast, and simple, making it a very popular way of assessing oxygenation in pediatric patients. However, there are few studies that establish the accuracy of this technology over a wide range of oxygen saturations in children. This study, done in 47 children aged from 1 day to 16 years with congenital heart disease and undergoing cardiac catheterization, compared the direct measurement of arterial oxygen saturation to values from pulse oximetry. Oxygen saturation was measured by an IL-282 Co-oximeter, which also measured carboxyhemoglobin and methemoglobin, and was compared to values obtained from both a Biox III and Nellcor N100. Both pusle oximeters gave values that closely correlated with the actual saturation (r = 0.91 and 0.93, respectively) with standard errors of the estimate of 4.1 and 3.2%, respectively. For both devices, the error increased with decreasing saturations, being progressively larger below a saturation of 80%. The difference between the actual saturation and that measured by pulse oximetry bore no relationship to the presence of carboxyhemoglobin, methemoglobin, fetal hemoglobin, bilirubin, cardiac index, or age of the patient. In conclusion, pulse oximetry, while a very useful technology in pediatrics, must be interpreted with some caution in children with severe cyanosis.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…