J. Heart Lung Transplant. · Jul 2009
Case ReportsVentricular assist device application with the intermediate use of a membrane oxygenator as a bridge to pediatric heart transplantation.
- Luis Garcia-Guereta, Javier Cabo, Pedro de la Oliva, Miguel Angel Villar, Lucia Deiros Bronte, Luis Goldman, and Michael Hübler.
- Department of Pediatric Cardiology, Hospital Universitario La Paz, Madrid, Spain. lguereta@arrakis.es
- J. Heart Lung Transplant. 2009 Jul 1;28(7):740-2.
AbstractExtracorporeal membrane oxygenation and ventricular assist devices are currently used for the treatment of severe heart failure as a bridge to transplantation. The use of ventricular assist devices is limited by respiratory failure. We report a patient with severe heart failure and respiratory failure who was successfully bridged to transplantation, initially with extracorporeal membrane oxygenation and afterwards with an EXCOR biventricular assist device (Berlin Heart AG, Berlin, Germany) and a membrane oxygenator (Jostra Quadrox D, Maquet Cardiopulmonary, AG Hirrlingen, Germany) intercalated in the outflow cannula of the left pump.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.