• Radiology · Sep 1996

    Comparative Study

    Power injection of intravenous contrast material through central venous catheters for CT: in vitro evaluation.

    • B R Herts, M A Cohen, B McInroy, W J Davros, R C Zepp, and D M Einstein.
    • Department of Radiology, Cleveland Clinic Foundation, OH 44195, USA.
    • Radiology. 1996 Sep 1;200(3):731-5.

    PurposeTo determine the feasibility of use of a power injector to deliver contrast material through central venous catheters for computed tomographic (CT) examinations.Materials And MethodsIoversol 240 and iothalamate meglumine 43% were separately injected through three 9.6-F Hickman catheters and three 10.0-F Leonard catheters with a power injector in an in vitro study. Flow rates of 1.0, 1.5, 2.0, and 2.5 mL/sec were tested. Peak pressures were mechanically recorded from two sites. A 95% prediction interval was calculated for each peak pressure, and the upper limits at the prediction interval were evaluated to determine if it was less than the recommended limit of 25 psi (175 kPa).ResultsContrast medium, flow rate, and catheter type each statistically significantly affected the measured peak pressures (P = .0001). For each flow rate tested, the upper limits of the prediction interval for the peak pressure at the connection between the coiled tubing and the catheter were below the manufacturer's specified peak pressure.ConclusionIn vitro analysis demonstrates that power injection of intravenous contrast medium through central venous catheters does not exceed the pressure limits of these catheters at the flow rates tested. In vivo testing to evaluate the safety and efficacy of power injection through central venous catheters is necessary.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…