• Spine J · Mar 2009

    Comparative Study

    Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation.

    • Ravi K Ponnappan, Hassan Serhan, Brett Zarda, Ravi Patel, Todd Albert, and Alexander R Vaccaro.
    • Department of Orthopaedic Surgery, Jefferson Medical College, 925 Chestnut Street, Philadelphia, PA 19107, USA. Ravi.Ponnappan@rothmaninstitute.com
    • Spine J. 2009 Mar 1;9(3):263-7.

    Background ContextPolyetheretherketone (PEEK) has been increasingly used as a biomaterial for spinal implants. PEEK lumbar fusion rods have recently become available for use in posterior lumbar fusion procedures.PurposeTo compare Polyetheretherketone Rod System to traditional titanium rod fixation in a cadaveric model and provide mechanical test data for the PEEK system.Study DesignBiomechanical testing.MethodsCadaveric biomechanical testing was conducted to compare Expedium 5.5 mm PEEK rods to titanium rods of equivalent diameter. Biomaterials testing was performed to determine static and dynamic performance of Expedium 5.5 mm PEEK rods with 6% BaSo4 in compressive bending and torsion.ResultsCadaveric testing demonstrated that PEEK rods can significantly reduce the range of motion of a destabilized segment. The testing showed no significant difference in the stability provided by PEEK and titanium rods in posterolateral fusion (PLF) or posterior lumbar interbody fusion (PLIF) constructs. PEEK static compressive bending tests showed 67 degrees displacement without fracture of the rod. Torsion testing showed 30 degrees of rotation without yield or plastic deformation. Dynamic compression testing revealed two fatigue runouts at 23 degrees.ConclusionsPEEK rods provide comparable stability to titanium rods of equivalent diameter in cadaveric testing. Mechanical testing suggests PEEK rods can withstand far beyond the angular displacements suggested by cadaveric testing and that of normal physiologic range of motion. Potential advantages to PEEK rods include better anterior column load sharing, reduced stress at bone-to-screw interface, and reduced computed tomography and magnetic resonance imaging scatter and artifact.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…