• Crit Care · Jan 2007

    Randomized Controlled Trial Comparative Study

    Comparison of cooling methods to induce and maintain normo- and hypothermia in intensive care unit patients: a prospective intervention study.

    • Cornelia W Hoedemaekers, Mustapha Ezzahti, Aico Gerritsen, and Johannes G van der Hoeven.
    • Department of Intensive Care, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands. C.Hoedemaekers@ic.umcn.nl
    • Crit Care. 2007 Jan 1;11(4):R91.

    BackgroundTemperature management is used with increased frequency as a tool to mitigate neurological injury. Although frequently used, little is known about the optimal cooling methods for inducing and maintaining controlled normo- and hypothermia in the intensive care unit (ICU). In this study we compared the efficacy of several commercially available cooling devices for temperature management in ICU patients with various types of neurological injury.MethodsFifty adult ICU patients with an indication for controlled mild hypothermia or strict normothermia were prospectively enrolled. Ten patients in each group were assigned in consecutive order to conventional cooling (that is, rapid infusion of 30 ml/kg cold fluids, ice and/or coldpacks), cooling with water circulating blankets, air circulating blankets, water circulating gel-coated pads and an intravascular heat exchange system. In all patients the speed of cooling (expressed as degrees C/h) was measured. After the target temperature was reached, we measured the percentage of time the patient's temperature was 0.2 degrees C below or above the target range. Rates of temperature decline over time were analyzed with one-way analysis of variance. Differences between groups were analyzed with one-way analysis of variance, with Bonferroni correction for multiple comparisons. A p < 0.05 was considered statistically significant.ResultsTemperature decline was significantly higher with the water-circulating blankets (1.33 +/- 0.63 degrees C/h), gel-pads (1.04 +/- 0.14 degrees C/h) and intravascular cooling (1.46 +/- 0.42 degrees C/h) compared to conventional cooling (0.31 +/- 0.23 degrees C/h) and the air-circulating blankets (0.18 +/- 0.2 degrees C/h) (p < 0.01). After the target temperature was reached, the intravascular cooling device was 11.2 +/- 18.7% of the time out of range, which was significantly less compared to all other methods.ConclusionCooling with water-circulating blankets, gel-pads and intravascular cooling is more efficient compared to conventional cooling and air-circulating blankets. The intravascular cooling system is most reliable to maintain a stable temperature.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.